CVE-2024-8705 (GCVE-0-2024-8705)

Vulnerability from cvelistv5 – Published: 2024-09-11 22:31 – Updated: 2024-09-12 16:21
VLAI
Title
Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System UCCGSrv.asmx GetDataKindByType sql injection
Summary
A vulnerability was found in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System 5.6.2 and classified as critical. Affected by this issue is the function GetDataKindByType of the file /DataSrvs/UCCGSrv.asmx. The manipulation leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-12 16:21 UTC
CWE
Assigner
VulDB CNA
References
URL Tags
https://vuldb.com/?id.277214 vdb-entrytechnical-description
https://vuldb.com/?ctiid.277214 signaturepermissions-required
https://vuldb.com/?submit.402236 third-party-advisory
https://wiki.shikangsi.com/post/share/3cd1d639-7b… exploit
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8705",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-12T16:21:34.867287Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-12T16:21:44.386Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Heating Network Wireless Monitoring System",
          "vendor": "Shandong Star Measurement and Control Equipment",
          "versions": [
            {
              "status": "affected",
              "version": "5.6.2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wiki (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System 5.6.2 and classified as critical. Affected by this issue is the function GetDataKindByType of the file /DataSrvs/UCCGSrv.asmx. The manipulation leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System 5.6.2 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion GetDataKindByType der Datei /DataSrvs/UCCGSrv.asmx. Durch die Manipulation mit unbekannten Daten kann eine sql injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-11T22:31:24.919Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-277214 | Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System UCCGSrv.asmx GetDataKindByType sql injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.277214"
        },
        {
          "name": "VDB-277214 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.277214"
        },
        {
          "name": "Submit #402236 | \u5c71\u4e1c\u601d\u8fbe\u7279\u6d4b\u63a7\u8bbe\u5907\u6709\u9650\u516c\u53f8 Hot Network Wireless Monitoring System 5.6.2 SQL Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.402236"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://wiki.shikangsi.com/post/share/3cd1d639-7b5d-47cf-a69d-552c314b5168"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-09-11T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-09-11T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-09-11T18:30:13.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System UCCGSrv.asmx GetDataKindByType sql injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-8705",
    "datePublished": "2024-09-11T22:31:24.919Z",
    "dateReserved": "2024-09-11T16:24:49.071Z",
    "dateUpdated": "2024-09-12T16:21:44.386Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8705",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-12T16:21:34.867287Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T16:21:40.396Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Heating Network Wireless Monitoring System",
              "vendor": "Shandong Star Measurement and Control Equipment",
              "versions": [
                {
                  "status": "affected",
                  "version": "5.6.2"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wiki (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System 5.6.2 and classified as critical. Affected by this issue is the function GetDataKindByType of the file /DataSrvs/UCCGSrv.asmx. The manipulation leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System 5.6.2 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion GetDataKindByType der Datei /DataSrvs/UCCGSrv.asmx. Durch die Manipulation mit unbekannten Daten kann eine sql injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-11T22:31:24.919Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-277214 | Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System UCCGSrv.asmx GetDataKindByType sql injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.277214"
            },
            {
              "name": "VDB-277214 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.277214"
            },
            {
              "name": "Submit #402236 | \u5c71\u4e1c\u601d\u8fbe\u7279\u6d4b\u63a7\u8bbe\u5907\u6709\u9650\u516c\u53f8 Hot Network Wireless Monitoring System 5.6.2 SQL Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.402236"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://wiki.shikangsi.com/post/share/3cd1d639-7b5d-47cf-a69d-552c314b5168"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-09-11T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-09-11T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-09-11T18:30:13.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System UCCGSrv.asmx GetDataKindByType sql injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8705",
        "datePublished": "2024-09-11T22:31:24.919Z",
        "dateReserved": "2024-09-11T16:24:49.071Z",
        "dateUpdated": "2024-09-11T22:31:24.919Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour