CVE-2024-8455 (GCVE-0-2024-8455)
Vulnerability from cvelistv5
Published
2024-09-30 07:24
Modified
2024-09-30 16:54
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-261 - Weak Encoding for Password
Summary
The swctrl service is used to detect and remotely manage PLANET Technology devices. For certain switch models, the authentication tokens used during communication with this service are encoded user passwords. Due to insufficient strength, unauthorized remote attackers who intercept the packets can directly crack them to obtain plaintext passwords.
References
| ► | URL | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ► | PLANET Technology | GS-4210-24PL4C hardware 2.0 |
Version: 0 < 2.305b240719 |
|||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_2.0:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gs-4210-24pl4c_hardware_2.0",
"vendor": "planet_technology_corp",
"versions": [
{
"lessThan": "2.305b240719",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_3.0:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gs-4210-24pl4c_hardware_3.0",
"vendor": "planet_technology_corp",
"versions": [
{
"lessThan": "3.305b240802",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:planet_technology_corp:igs-5225-4up1t2s_hardware_1.0:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "igs-5225-4up1t2s_hardware_1.0",
"vendor": "planet_technology_corp",
"versions": [
{
"status": "affected",
"version": "0"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8455",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T16:51:56.909491Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T16:54:36.168Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GS-4210-24PL4C hardware 2.0",
"vendor": "PLANET Technology",
"versions": [
{
"lessThan": "2.305b240719",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GS-4210-24P2S hardware 3.0",
"vendor": "PLANET Technology",
"versions": [
{
"lessThan": "3.305b240802",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IGS-5225-4UP1T2S hardware 1.0",
"vendor": "PLANET Technology",
"versions": [
{
"status": "affected",
"version": "0"
}
]
}
],
"datePublic": "2024-09-30T07:24:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The swctrl service is used to detect and remotely manage PLANET Technology devices. For certain switch models, the authentication tokens used during communication with this service are encoded user passwords. Due to insufficient strength, unauthorized remote attackers who intercept the packets can directly crack them to obtain plaintext passwords."
}
],
"value": "The swctrl service is used to detect and remotely manage PLANET Technology devices. For certain switch models, the authentication tokens used during communication with this service are encoded user passwords. Due to insufficient strength, unauthorized remote attackers who intercept the packets can directly crack them to obtain plaintext passwords."
}
],
"impacts": [
{
"capecId": "CAPEC-97",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-97 Cryptanalysis"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-261",
"description": "CWE-261 Weak Encoding for Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T07:25:13.087Z",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.twcert.org.tw/tw/cp-132-8059-bde5f-1.html"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.twcert.org.tw/en/cp-139-8060-f3955-2.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update firmware of GS-4210-24PL4C hardware 2.0 to version 2.305b240719 or later.\u003cbr\u003eUpdate firmware of GS-4210-24P2S hardware 3.0 to version 3.305b240802 or later.\u003cbr\u003eIGS-5225-4UP1T2S hardware 1.0 has reached End of Life (EOL). Replacement is recommended.\u003cbr\u003e"
}
],
"value": "Update firmware of GS-4210-24PL4C hardware 2.0 to version 2.305b240719 or later.\nUpdate firmware of GS-4210-24P2S hardware 3.0 to version 3.305b240802 or later.\nIGS-5225-4UP1T2S hardware 1.0 has reached End of Life (EOL). Replacement is recommended."
}
],
"source": {
"advisory": "TVN-202409011",
"discovery": "EXTERNAL"
},
"title": "PLANET Technology switch devices - Swctrl service exchanges weakly encoded passwords",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2024-8455",
"datePublished": "2024-09-30T07:24:49.379Z",
"dateReserved": "2024-09-05T02:53:08.080Z",
"dateUpdated": "2024-09-30T16:54:36.168Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-8455\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-30T16:51:56.909491Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_2.0:*:*:*:*:*:*:*:*\"], \"vendor\": \"planet_technology_corp\", \"product\": \"gs-4210-24pl4c_hardware_2.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.305b240719\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_3.0:*:*:*:*:*:*:*:*\"], \"vendor\": \"planet_technology_corp\", \"product\": \"gs-4210-24pl4c_hardware_3.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.305b240802\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:planet_technology_corp:igs-5225-4up1t2s_hardware_1.0:*:*:*:*:*:*:*:*\"], \"vendor\": \"planet_technology_corp\", \"product\": \"igs-5225-4up1t2s_hardware_1.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-30T16:54:29.090Z\"}}], \"cna\": {\"title\": \"PLANET Technology switch devices - Swctrl service exchanges weakly encoded passwords\", \"source\": {\"advisory\": \"TVN-202409011\", \"discovery\": \"EXTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-97\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-97 Cryptanalysis\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"PLANET Technology\", \"product\": \"GS-4210-24PL4C hardware 2.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.305b240719\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"PLANET Technology\", \"product\": \"GS-4210-24P2S hardware 3.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.305b240802\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"PLANET Technology\", \"product\": \"IGS-5225-4UP1T2S hardware 1.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Update firmware of GS-4210-24PL4C hardware 2.0 to version 2.305b240719 or later.\\nUpdate firmware of GS-4210-24P2S hardware 3.0 to version 3.305b240802 or later.\\nIGS-5225-4UP1T2S hardware 1.0 has reached End of Life (EOL). Replacement is recommended.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Update firmware of GS-4210-24PL4C hardware 2.0 to version 2.305b240719 or later.\u003cbr\u003eUpdate firmware of GS-4210-24P2S hardware 3.0 to version 3.305b240802 or later.\u003cbr\u003eIGS-5225-4UP1T2S hardware 1.0 has reached End of Life (EOL). Replacement is recommended.\u003cbr\u003e\", \"base64\": false}]}], \"datePublic\": \"2024-09-30T07:24:00.000Z\", \"references\": [{\"url\": \"https://www.twcert.org.tw/tw/cp-132-8059-bde5f-1.html\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://www.twcert.org.tw/en/cp-139-8060-f3955-2.html\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The swctrl service is used to detect and remotely manage PLANET Technology devices. For certain switch models, the authentication tokens used during communication with this service are encoded user passwords. Due to insufficient strength, unauthorized remote attackers who intercept the packets can directly crack them to obtain plaintext passwords.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The swctrl service is used to detect and remotely manage PLANET Technology devices. For certain switch models, the authentication tokens used during communication with this service are encoded user passwords. Due to insufficient strength, unauthorized remote attackers who intercept the packets can directly crack them to obtain plaintext passwords.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-261\", \"description\": \"CWE-261 Weak Encoding for Password\"}]}], \"providerMetadata\": {\"orgId\": \"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e\", \"shortName\": \"twcert\", \"dateUpdated\": \"2024-09-30T07:25:13.087Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-8455\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-30T16:54:36.168Z\", \"dateReserved\": \"2024-09-05T02:53:08.080Z\", \"assignerOrgId\": \"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e\", \"datePublished\": \"2024-09-30T07:24:49.379Z\", \"assignerShortName\": \"twcert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…