CVE-2024-8075 (GCVE-0-2024-8075)
Vulnerability from cvelistv5
Published
2024-08-22 19:31
Modified
2024-08-23 14:51
Severity ?
5.3 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - OS Command Injection
Summary
A vulnerability has been found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 and classified as critical. Affected by this vulnerability is the function setDiagnosisCfg. The manipulation leads to os command injection. The attack can be launched remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8075",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T14:11:44.066460Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T14:51:18.091Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1200 T8",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.1.5cu.862_B20230228"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "FPT IS Security (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 and classified as critical. Affected by this vulnerability is the function setDiagnosisCfg. The manipulation leads to os command injection. The attack can be launched remotely. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In TOTOLINK AC1200 T8 4.1.5cu.862_B20230228 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion setDiagnosisCfg. Durch das Manipulieren mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T19:31:05.823Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-275557 | TOTOLINK AC1200 T8 setDiagnosisCfg os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.275557"
},
{
"name": "VDB-275557 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.275557"
},
{
"name": "Submit #390929 | TOTOLINK AC1200 T8 V4.1.5cu.862_B20230228 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.390929"
},
{
"tags": [
"related"
],
"url": "https://github.com/hawkteam404/RnD_Public/blob/main/TOTOLink_AC1200_T8_OsCmdI_BOF.md"
},
{
"tags": [
"product"
],
"url": "https://www.totolink.net/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-08-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-22T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-22T14:26:23.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK AC1200 T8 setDiagnosisCfg os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-8075",
"datePublished": "2024-08-22T19:31:05.823Z",
"dateReserved": "2024-08-22T12:20:50.961Z",
"dateUpdated": "2024-08-23T14:51:18.091Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…