CVE-2024-7987 (GCVE-0-2024-7987)
Vulnerability from cvelistv5 – Published: 2024-08-26 14:40 – Updated: 2024-08-26 17:29
VLAI
EPSS
VEX
Title
Rockwell Automation ThinManager® ThinServer™ Information Disclosure and Remote Code Execution Vulnerabilities
Summary
A remote code execution vulnerability exists in the Rockwell Automation ThinManager® ThinServer™
that allows a threat actor to execute arbitrary code with System privileges. To exploit this vulnerability and a threat actor must abuse the ThinServer™ service by creating a junction and use it to upload arbitrary files.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-26 17:20 UTC
CWE
- ThinManager® ThinServer™ Remote Code Execution
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
Rockwell
CNA
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | ThinManager® ThinServer™ |
Affected:
11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1
|
|
| rockwellautomation | thinmanager_thinserver |
Affected:
11.1.0 , ≤ 11.1.7
(custom)
Affected: 11.2.0 , ≤ 11.2.8 (custom) Affected: 12.0.0 , ≤ 12.0.6 (custom) Affected: 12.1.0 , ≤ 12.1.7 (custom) Affected: 13.0.0 , ≤ 13.0.4 (custom) Affected: 13.1.0 , ≤ 13.1.2 (custom) Affected: 13.2.0 , ≤ 13.2.1 (custom) cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:* |
Date Public
2024-08-26 13:00
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "thinmanager_thinserver",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "11.1.7",
"status": "affected",
"version": "11.1.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "11.2.8",
"status": "affected",
"version": "11.2.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.0.6",
"status": "affected",
"version": "12.0.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.1.7",
"status": "affected",
"version": "12.1.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.0.4",
"status": "affected",
"version": "13.0.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.1.2",
"status": "affected",
"version": "13.1.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.2.1",
"status": "affected",
"version": "13.2.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7987",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-26T17:20:29.756565Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-26T17:29:09.449Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinManager\u00ae ThinServer\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"
}
]
}
],
"datePublic": "2024-08-26T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA remote code execution vulnerability exists in the Rockwell Automation\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThinManager\u00ae ThinServer\u2122\u003c/span\u003e\nthat allows a threat actor to execute arbitrary code with System privileges. To exploit this vulnerability and a threat actor must abuse the ThinServer\u2122 service by creating a junction and use it to upload arbitrary files.\u0026nbsp;\u003c/span\u003e"
}
],
"value": "A remote code execution vulnerability exists in the Rockwell Automation\u00a0ThinManager\u00ae ThinServer\u2122\nthat allows a threat actor to execute arbitrary code with System privileges. To exploit this vulnerability and a threat actor must abuse the ThinServer\u2122 service by creating a junction and use it to upload arbitrary files."
}
],
"impacts": [
{
"capecId": "CAPEC-576",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-576 Group Permission Footprinting"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "ThinManager\u00ae ThinServer\u2122 Remote Code Execution",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-26T14:40:29.255Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003effected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in software version\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in software version\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eThinManager\u00ae ThinServer\u2122\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.0-11.1.7\u003cbr\u003e11.2.0-11.2.8\u003cbr\u003e12.0.0-12.0.6\u003cbr\u003e12.1.0-12.1.7\u003cbr\u003e13.0.0-13.0.4\u003cbr\u003e13.1.0-13.1.2\u003cbr\u003e13.2.0-13.2.1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.8\u003c/p\u003e\u003cp\u003e11.2.9\u003c/p\u003e\u003cp\u003e12.0.7\u003c/p\u003e\u003cp\u003e12.1.8\u003c/p\u003e\u003cp\u003e13.0.5\u003c/p\u003e\u003cp\u003e13.1.3\u003c/p\u003e\u003cp\u003e13.2.2\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\n\n\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "ffected Product\n\nFirst Known in software version\n\nCorrected in software version\n\nThinManager\u00ae ThinServer\u2122\n\n11.1.0-11.1.7\n11.2.0-11.2.8\n12.0.0-12.0.6\n12.1.0-12.1.7\n13.0.0-13.0.4\n13.1.0-13.1.2\n13.2.0-13.2.1\n\n11.1.8\n\n11.2.9\n\n12.0.7\n\n12.1.8\n\n13.0.5\n\n13.1.3\n\n13.2.2\n\n\n\n\nMitigations and Workarounds\n\nCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "SD1692",
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation ThinManager\u00ae ThinServer\u2122 Information Disclosure and Remote Code Execution Vulnerabilities",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7987",
"datePublished": "2024-08-26T14:40:29.255Z",
"dateReserved": "2024-08-19T20:06:26.723Z",
"dateUpdated": "2024-08-26T17:29:09.449Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:rockwellautomation:thinmanager_thinserver:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "thinmanager_thinserver",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "11.1.7",
"status": "affected",
"version": "11.1.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "11.2.8",
"status": "affected",
"version": "11.2.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.0.6",
"status": "affected",
"version": "12.0.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.1.7",
"status": "affected",
"version": "12.1.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.0.4",
"status": "affected",
"version": "13.0.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.1.2",
"status": "affected",
"version": "13.1.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "13.2.1",
"status": "affected",
"version": "13.2.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7987",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-26T17:20:29.756565Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-26T17:28:58.329Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinManager\u00ae ThinServer\u2122",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"
}
]
}
],
"datePublic": "2024-08-26T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA remote code execution vulnerability exists in the Rockwell Automation\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThinManager\u00ae ThinServer\u2122\u003c/span\u003e\nthat allows a threat actor to execute arbitrary code with System privileges. To exploit this vulnerability and a threat actor must abuse the ThinServer\u2122 service by creating a junction and use it to upload arbitrary files.\u0026nbsp;\u003c/span\u003e"
}
],
"value": "A remote code execution vulnerability exists in the Rockwell Automation\u00a0ThinManager\u00ae ThinServer\u2122\nthat allows a threat actor to execute arbitrary code with System privileges. To exploit this vulnerability and a threat actor must abuse the ThinServer\u2122 service by creating a junction and use it to upload arbitrary files."
}
],
"impacts": [
{
"capecId": "CAPEC-576",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-576 Group Permission Footprinting"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "ThinManager\u00ae ThinServer\u2122 Remote Code Execution",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-26T14:40:29.255Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003effected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in software version\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in software version\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eThinManager\u00ae ThinServer\u2122\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.0-11.1.7\u003cbr\u003e11.2.0-11.2.8\u003cbr\u003e12.0.0-12.0.6\u003cbr\u003e12.1.0-12.1.7\u003cbr\u003e13.0.0-13.0.4\u003cbr\u003e13.1.0-13.1.2\u003cbr\u003e13.2.0-13.2.1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e11.1.8\u003c/p\u003e\u003cp\u003e11.2.9\u003c/p\u003e\u003cp\u003e12.0.7\u003c/p\u003e\u003cp\u003e12.1.8\u003c/p\u003e\u003cp\u003e13.0.5\u003c/p\u003e\u003cp\u003e13.1.3\u003c/p\u003e\u003cp\u003e13.2.2\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\n\n\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "ffected Product\n\nFirst Known in software version\n\nCorrected in software version\n\nThinManager\u00ae ThinServer\u2122\n\n11.1.0-11.1.7\n11.2.0-11.2.8\n12.0.0-12.0.6\n12.1.0-12.1.7\n13.0.0-13.0.4\n13.1.0-13.1.2\n13.2.0-13.2.1\n\n11.1.8\n\n11.2.9\n\n12.0.7\n\n12.1.8\n\n13.0.5\n\n13.1.3\n\n13.2.2\n\n\n\n\nMitigations and Workarounds\n\nCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "SD1692",
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation ThinManager\u00ae ThinServer\u2122 Information Disclosure and Remote Code Execution Vulnerabilities",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-7987",
"datePublished": "2024-08-26T14:40:29.255Z",
"dateReserved": "2024-08-19T20:06:26.723Z",
"dateUpdated": "2024-08-26T17:29:09.449Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.