CVE-2024-7513 (GCVE-0-2024-7513)

Vulnerability from cvelistv5 – Published: 2024-08-14 19:48 – Updated: 2025-08-15 13:03
VLAI
Title
Rockwell Automation FactoryTalk® View Site Edition Code Execution Vulnerability via File Permissions
Summary
CVE-2024-7513 IMPACT A code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-14 20:09 UTC
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
Rockwell CNA
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk View Site Edition Affected: 13.0
Create a notification for this product.
rockwellautomation factorytalk_view Affected: 13.0
    cpe:2.3:a:rockwellautomation:factorytalk_view:13.0:*:*:*:se:*:*:*
Create a notification for this product.
Date Public
2024-08-13 13:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:factorytalk_view:13.0:*:*:*:se:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "factorytalk_view",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "13.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7513",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-14T20:09:08.721442Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-14T20:16:25.948Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk View Site Edition",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "13.0"
            }
          ]
        }
      ],
      "datePublic": "2024-08-13T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cb\u003eCVE-2024-7513 IMPACT\u003c/b\u003e\u003c/p\u003e\u003cp\u003eA code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions.\u003c/p\u003e"
            }
          ],
          "value": "CVE-2024-7513 IMPACT\n\nA code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-576",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-576 Group Permission Footprinting"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-15T13:03:12.526Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201688.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v15.0"
            }
          ],
          "value": "Upgrade to v15.0"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae View Site Edition Code Execution Vulnerability via File Permissions",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eCustomers using the affected software are encouraged to apply security best practices, if possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eRemove \u201cEveryone\u201d user group from read and write privileges by changing the FactoryTalk\u00ae View SE project folder permissions using the help guide. Detailed instructions are below. \u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eOpen FactoryTalk\u00ae View Studio -\u0026gt; Help -\u0026gt; FactoryTalk\u00ae View SE Help. I\u003cspan style=\"background-color: var(--wht);\"\u003en the file -\u0026gt; Security -\u0026gt; \u201cHMI projects folder\u201d\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Customers using the affected software are encouraged to apply security best practices, if possible.\n\n  *  Remove \u201cEveryone\u201d user group from read and write privileges by changing the FactoryTalk\u00ae View SE project folder permissions using the help guide. Detailed instructions are below. \n\n\n\n\n  *  Open FactoryTalk\u00ae View Studio -\u003e Help -\u003e FactoryTalk\u00ae View SE Help. In the file -\u003e Security -\u003e \u201cHMI projects folder\u201d"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-7513",
    "datePublished": "2024-08-14T19:48:46.656Z",
    "dateReserved": "2024-08-05T20:18:13.759Z",
    "dateUpdated": "2025-08-15T13:03:12.526Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:rockwellautomation:factorytalk_view:13.0:*:*:*:se:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "factorytalk_view",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "13.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7513",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-14T20:09:08.721442Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-14T20:16:19.702Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk View Site Edition",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "13.0"
                }
              ]
            }
          ],
          "datePublic": "2024-08-13T13:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\u003cb\u003eCVE-2024-7513 IMPACT\u003c/b\u003e\u003c/p\u003e\u003cp\u003eA code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions.\u003c/p\u003e"
                }
              ],
              "value": "CVE-2024-7513 IMPACT\n\nA code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-576",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-576 Group Permission Footprinting"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-15T13:03:12.526Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201688.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v15.0"
                }
              ],
              "value": "Upgrade to v15.0"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk\u00ae View Site Edition Code Execution Vulnerability via File Permissions",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eCustomers using the affected software are encouraged to apply security best practices, if possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eRemove \u201cEveryone\u201d user group from read and write privileges by changing the FactoryTalk\u00ae View SE project folder permissions using the help guide. Detailed instructions are below. \u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eOpen FactoryTalk\u00ae View Studio -\u0026gt; Help -\u0026gt; FactoryTalk\u00ae View SE Help. I\u003cspan style=\"background-color: var(--wht);\"\u003en the file -\u0026gt; Security -\u0026gt; \u201cHMI projects folder\u201d\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Customers using the affected software are encouraged to apply security best practices, if possible.\n\n  *  Remove \u201cEveryone\u201d user group from read and write privileges by changing the FactoryTalk\u00ae View SE project folder permissions using the help guide. Detailed instructions are below. \n\n\n\n\n  *  Open FactoryTalk\u00ae View Studio -\u003e Help -\u003e FactoryTalk\u00ae View SE Help. In the file -\u003e Security -\u003e \u201cHMI projects folder\u201d"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2024-7513",
        "datePublished": "2024-08-14T19:48:46.656Z",
        "dateReserved": "2024-08-05T20:18:13.759Z",
        "dateUpdated": "2025-08-15T13:03:12.526Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.