CVE-2024-7335 (GCVE-0-2024-7335)
Vulnerability from cvelistv5
Published
2024-08-01 02:00
Modified
2024-08-06 19:39
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Overflow
Summary
A vulnerability classified as critical has been found in TOTOLINK EX200 4.0.3c.7646_B20201211. Affected is the function getSaveConfig of the file /cgi-bin/cstecgi.cgi?action=save&setting. The manipulation of the argument http_host leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-273258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:totolink:ex200_firmware:4.0.3c.7646_b20201211:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ex200_firmware",
"vendor": "totolink",
"versions": [
{
"status": "affected",
"version": "4.0.3c.7646_b20201211"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7335",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T19:38:43.936600Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:39:28.167Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EX200",
"vendor": "TOTOLINK",
"versions": [
{
"status": "affected",
"version": "4.0.3c.7646_B20201211"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in TOTOLINK EX200 4.0.3c.7646_B20201211. Affected is the function getSaveConfig of the file /cgi-bin/cstecgi.cgi?action=save\u0026setting. The manipulation of the argument http_host leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-273258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in TOTOLINK EX200 4.0.3c.7646_B20201211 entdeckt. Dabei betrifft es die Funktion getSaveConfig der Datei /cgi-bin/cstecgi.cgi?action=save\u0026setting. Durch das Manipulieren des Arguments http_host mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T02:00:06.560Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273258 | TOTOLINK EX200 getSaveConfig buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273258"
},
{
"name": "VDB-273258 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273258"
},
{
"name": "Submit #379313 | TOTOLINK EX200 V4.0.3c.7646_B20201211 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.379313"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/EX200/getSaveConfig.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-31T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-31T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-31T14:35:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOTOLINK EX200 getSaveConfig buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7335",
"datePublished": "2024-08-01T02:00:06.560Z",
"dateReserved": "2024-07-31T12:30:18.894Z",
"dateUpdated": "2024-08-06T19:39:28.167Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…