CVE-2024-5634 (GCVE-0-2024-5634)
Vulnerability from cvelistv5
Published
2024-07-09 10:58
Modified
2024-08-01 21:18
CWE
Summary
Longse model LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy.  Additionally, every camera with the same firmware version shares the same password.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:longse_technology:lbh30fe200w:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "lbh30fe200w",
            "vendor": "longse_technology",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:zamel:zmb-01:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "zmb-01",
            "vendor": "zamel",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5634",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-15T21:27:13.841284Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-15T21:29:00.919Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.724Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "product",
              "x_transferred"
            ],
            "url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01"
          },
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/"
          },
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://cert.pl/posts/2024/07/CVE-2024-5631/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "LBH30FE200W",
          "vendor": "Longse Technology",
          "versions": [
            {
              "lessThanOrEqual": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ZMB-01/C",
          "vendor": "Zamel",
          "versions": [
            {
              "lessThanOrEqual": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Adam Zambrzycki"
        }
      ],
      "datePublic": "2024-07-09T10:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Longse model\u0026nbsp;LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy.\u0026nbsp;\u003cbr\u003eAdditionally, every camera with the same firmware version shares the same password.\u0026nbsp;"
            }
          ],
          "value": "Longse model\u00a0LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy.\u00a0\nAdditionally, every camera with the same firmware version shares the same password."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-49",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-49 Password Brute Forcing"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1391",
              "description": "CWE-1391 Use of Weak Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T10:58:47.153Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "product"
          ],
          "url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/posts/2024/07/CVE-2024-5631/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "unsupported-when-assigned"
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2024-5634",
    "datePublished": "2024-07-09T10:58:47.153Z",
    "dateReserved": "2024-06-04T14:42:05.336Z",
    "dateUpdated": "2024-08-01T21:18:06.724Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01\", \"tags\": [\"product\", \"x_transferred\"]}, {\"url\": \"https://cert.pl/en/posts/2024/07/CVE-2024-5631/\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}, {\"url\": \"https://cert.pl/posts/2024/07/CVE-2024-5631/\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T21:18:06.724Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-5634\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-15T21:27:13.841284Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:longse_technology:lbh30fe200w:-:*:*:*:*:*:*:*\"], \"vendor\": \"longse_technology\", \"product\": \"lbh30fe200w\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:h:zamel:zmb-01:-:*:*:*:*:*:*:*\"], \"vendor\": \"zamel\", \"product\": \"zmb-01\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-15T21:28:49.655Z\"}}], \"cna\": {\"tags\": [\"unsupported-when-assigned\"], \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Adam Zambrzycki\"}], \"impacts\": [{\"capecId\": \"CAPEC-49\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-49 Password Brute Forcing\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.6, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Longse Technology\", \"product\": \"LBH30FE200W\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"affected\"}, {\"vendor\": \"Zamel\", \"product\": \"ZMB-01/C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"affected\"}], \"datePublic\": \"2024-07-09T10:00:00.000Z\", \"references\": [{\"url\": \"https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01\", \"tags\": [\"product\"]}, {\"url\": \"https://cert.pl/en/posts/2024/07/CVE-2024-5631/\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://cert.pl/posts/2024/07/CVE-2024-5631/\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Longse model\\u00a0LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy.\\u00a0\\nAdditionally, every camera with the same firmware version shares the same password.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Longse model\u0026nbsp;LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy.\u0026nbsp;\u003cbr\u003eAdditionally, every camera with the same firmware version shares the same password.\u0026nbsp;\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1391\", \"description\": \"CWE-1391 Use of Weak Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"4bb8329e-dd38-46c1-aafb-9bf32bcb93c6\", \"shortName\": \"CERT-PL\", \"dateUpdated\": \"2024-07-09T10:58:47.153Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-5634\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T21:18:06.724Z\", \"dateReserved\": \"2024-06-04T14:42:05.336Z\", \"assignerOrgId\": \"4bb8329e-dd38-46c1-aafb-9bf32bcb93c6\", \"datePublished\": \"2024-07-09T10:58:47.153Z\", \"assignerShortName\": \"CERT-PL\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…