CVE-2024-43649 (GCVE-0-2024-43649)
Vulnerability from cvelistv5
Published
2025-01-09 07:56
Modified
2025-03-11 13:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
References
| ► | URL | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Version: 0 < 24120701 |
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43649",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:35:10.473442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:36:23.194Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Authenticated command injection in the filename of a \u0026lt;redacted\u0026gt;.exe request leads to remote code execution as the root user.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u0026lt;redacted\u0026gt; fields. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a payload.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification:\u0026nbsp;This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \"pivot\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y)."
}
],
"value": "Authenticated command injection in the filename of a \u003credacted\u003e.exe request leads to remote code execution as the root user.\n\nThis issue affects Iocharger firmware for AC models before version 24120701.\n\nLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u003credacted\u003e fields. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a payload.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\n\nCVSS clarification:\u00a0This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \"pivot\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:05.672Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43649/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection via \u003credacted\u003e.exe \u003credacted\u003e parameter",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43649",
"datePublished": "2025-01-09T07:56:46.982Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:05.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-43649\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-09T14:35:10.473442Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-09T14:36:16.749Z\"}}], \"cna\": {\"title\": \"Authenticated command injection via \u003credacted\u003e.exe \u003credacted\u003e parameter\", \"source\": {\"advisory\": \"DIVD-2024-00035\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Wilco van Beijnum\"}, {\"lang\": \"en\", \"type\": \"analyst\", \"value\": \"Harm van den Brink (DIVD)\"}, {\"lang\": \"en\", \"type\": \"analyst\", \"value\": \"Frank Breedijk (DIVD)\"}], \"impacts\": [{\"capecId\": \"CAPEC-88\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-88 OS Command Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"PRESENT\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"YES\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"LOW\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"LOW\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Iocharger\", \"product\": \"Iocharger firmware for AC models\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"24120701\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-01-09T00:00:00.000Z\", \"references\": [{\"url\": \"https://csirt.divd.nl/DIVD-2024-00035/\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://csirt.divd.nl/CVE-2024-43649/\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://iocharger.com\", \"tags\": [\"product\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Authenticated command injection in the filename of a \u003credacted\u003e.exe request leads to remote code execution as the root user.\\n\\nThis issue affects Iocharger firmware for AC models before version 24120701.\\n\\nLikelihood: Moderate \\u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u003credacted\u003e fields. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a payload.\\n\\nImpact: Critical \\u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\\n\\nCVSS clarification:\\u00a0This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \\\"pivot\\\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Authenticated command injection in the filename of a \u0026lt;redacted\u0026gt;.exe request leads to remote code execution as the root user.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \\u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u0026lt;redacted\u0026gt; fields. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a payload.\u003cbr\u003e\u003cbr\u003eImpact: Critical \\u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification:\u0026nbsp;This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \\\"pivot\\\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-250\", \"description\": \"CWE-250: Execution with Unnecessary Privileges\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"description\": \"OWASP-A03: Injection\"}]}], \"providerMetadata\": {\"orgId\": \"b87402ff-ae37-4194-9dae-31abdbd6f217\", \"shortName\": \"DIVD\", \"dateUpdated\": \"2025-03-11T13:07:05.672Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-43649\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-11T13:07:05.672Z\", \"dateReserved\": \"2024-08-14T09:27:41.767Z\", \"assignerOrgId\": \"b87402ff-ae37-4194-9dae-31abdbd6f217\", \"datePublished\": \"2025-01-09T07:56:46.982Z\", \"assignerShortName\": \"DIVD\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…