CVE-2024-41913 (GCVE-0-2024-41913)
Vulnerability from cvelistv5
Published
2024-08-06 13:57
Modified
2025-03-19 15:21
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly sanitize User input.
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Version: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41913",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-19T15:20:42.654177Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-434",
                "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T15:21:17.519Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices.  The firmware flaw does not properly sanitize User input."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T13:57:29.551Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006488-11006512-16/hpsbpy03957"
        }
      ],
      "title": "Clariti Manager \u2013 Arbitrary File Upload",
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41913",
    "datePublished": "2024-08-06T13:57:29.551Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-19T15:21:17.519Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-41913\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-19T15:20:42.654177Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-434\", \"description\": \"CWE-434 Unrestricted Upload of File with Dangerous Type\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-07T15:48:54.157Z\"}}], \"cna\": {\"title\": \"Clariti Manager \\u2013 Arbitrary File Upload\", \"affected\": [{\"vendor\": \"HP Inc.\", \"product\": \"Poly Clariti Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"See HP Security Bulletin reference for affected versions.\"}]}], \"references\": [{\"url\": \"https://support.hp.com/us-en/document/ish_11006488-11006512-16/hpsbpy03957\"}], \"x_generator\": {\"engine\": \"cveClient/1.0.15\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices.  The firmware flaw does not properly sanitize User input.\"}], \"providerMetadata\": {\"orgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"shortName\": \"hp\", \"dateUpdated\": \"2024-08-06T13:57:29.551Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-41913\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-19T15:21:17.519Z\", \"dateReserved\": \"2024-07-23T15:33:15.305Z\", \"assignerOrgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"datePublished\": \"2024-08-06T13:57:29.551Z\", \"assignerShortName\": \"hp\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…