CVE-2024-4169 (GCVE-0-2024-4169)
Vulnerability from cvelistv5
Published
2024-04-25 12:31
Modified
2024-08-01 20:33
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Tenda 4G300 Version: 1.01.42
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "4g300",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.01.42"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4169",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-25T16:16:36.621949Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:55:55.670Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.514Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261988 | Tenda 4G300 sub_4279CC stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261988"
          },
          {
            "name": "VDB-261988 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261988"
          },
          {
            "name": "Submit #318988 | Tenda 4G300 V1.01.42 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318988"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_42775C.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.01.42"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda 4G300 1.01.42 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion sub_42775C/sub_4279CC. Dank Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T12:31:04.756Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261988 | Tenda 4G300 sub_4279CC stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261988"
        },
        {
          "name": "VDB-261988 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261988"
        },
        {
          "name": "Submit #318988 | Tenda 4G300 V1.01.42 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318988"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_42775C.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 sub_4279CC stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4169",
    "datePublished": "2024-04-25T12:31:04.756Z",
    "dateReserved": "2024-04-25T04:41:33.737Z",
    "dateUpdated": "2024-08-01T20:33:52.514Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…