CVE-2024-38296 (GCVE-0-2024-38296)
Vulnerability from cvelistv5
Published
2024-11-22 02:58
Modified
2024-12-09 15:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1421 - Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution
Summary
Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Edge Gateway 5200 |
Version: N/A ≤ |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "edge_gateway_5200_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "12.0.94.2380",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-38296",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T18:18:21.316783Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T18:20:39.113Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Edge Gateway 5200",
"vendor": "Dell",
"versions": [
{
"lessThan": "12.0.94.2380",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank the Eclypsium Research Team for reporting this issue"
}
],
"datePublic": "2024-11-21T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1421",
"description": "CWE-1421: Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T15:03:06.924Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-38296",
"datePublished": "2024-11-22T02:58:27.660Z",
"dateReserved": "2024-06-13T14:41:01.525Z",
"dateUpdated": "2024-12-09T15:03:06.924Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-38296\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-25T18:18:21.316783Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:dell:edge_gateway_5200_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"dell\", \"product\": \"edge_gateway_5200_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"12.0.94.2380\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-25T18:20:33.374Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Dell would like to thank the Eclypsium Research Team for reporting this issue\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.7, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"Edge Gateway 5200\", \"versions\": [{\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"12.0.94.2380\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-11-21T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000250949/dsa-2024-345-security-update-for-dell-networking-edge-gateway-5200-vulnerability\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell Edge Gateway 3200, versions prior to 15.40.30.2879, and Edge Gateway 5200, versions prior to 12.0.94.2380, contain an Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1421\", \"description\": \"CWE-1421: Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-12-09T15:03:06.924Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-38296\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-09T15:03:06.924Z\", \"dateReserved\": \"2024-06-13T14:41:01.525Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-11-22T02:58:27.660Z\", \"assignerShortName\": \"dell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…