CVE-2024-3742 (GCVE-0-2024-3742)
Vulnerability from cvelistv5
Published
2024-04-18 22:15
Modified
2024-08-01 20:20
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Summary
Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrolink | Compact DAB Transmitter |
Version: 10W Version: 100W Version: 250W |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:electrolink:medium_dab_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "medium dab transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "2kW, 1kW, 500W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:digital_fm_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "digital fm transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "15W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:vhf_tv_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vhf tv transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "BI"
},
{
"status": "affected",
"version": "BIII"
},
{
"status": "affected",
"version": "10W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:high_power_dab_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "high power dab transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "5kW"
},
{
"status": "affected",
"version": "4kW"
},
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "2.5kW"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:compact_dab_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact dab transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "10W"
},
{
"status": "affected",
"version": "100W"
},
{
"status": "affected",
"version": "250W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:modular_fm_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modular fm transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "5kW"
},
{
"status": "affected",
"version": "10kW"
},
{
"status": "affected",
"version": "15kW"
},
{
"status": "affected",
"version": "20kW"
},
{
"status": "affected",
"version": "30kW"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:compact_fm_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact fm transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "500W"
},
{
"status": "affected",
"version": "1kW"
},
{
"status": "affected",
"version": "2kW"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3742",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-07T15:38:32.607032Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:32:02.128Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:20:00.923Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Compact DAB Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "10W"
},
{
"status": "affected",
"version": "100W"
},
{
"status": "affected",
"version": "250W"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Medium DAB Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "500W"
},
{
"status": "affected",
"version": "1kW"
},
{
"status": "affected",
"version": "2kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "High Power DAB Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "2.5kW"
},
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "4kW"
},
{
"status": "affected",
"version": "5kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact FM Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "Compact FM Transmitter"
},
{
"status": "affected",
"version": "500W"
},
{
"status": "affected",
"version": "1kW"
},
{
"status": "affected",
"version": "2kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modular FM Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "5kW"
},
{
"status": "affected",
"version": "10kW"
},
{
"status": "affected",
"version": "15kW"
},
{
"status": "affected",
"version": "20kW"
},
{
"status": "affected",
"version": "30kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital FM Transmitter",
"vendor": "Electrolink",
"versions": [
{
"lessThanOrEqual": "40kW",
"status": "affected",
"version": "15W",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VHF TV Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "BI"
},
{
"status": "affected",
"version": "BIII"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UHF TV Transmitter",
"vendor": "Electrolink",
"versions": [
{
"lessThanOrEqual": "5kW",
"status": "affected",
"version": "10W",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gjoko Krstic publicly reported these vulnerabilities on the internet after an unsuccessful attempt to contact Electrolink directly."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system."
}
],
"value": "Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-28T16:52:22.524Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02"
}
],
"source": {
"advisory": "ICSA-24-107-02",
"discovery": "EXTERNAL"
},
"title": "Electrolink FM/DAB/TV Transmitter Cleartext Storage of Sensitive Information",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Electrolink has not responded to requests to work with CISA to mitigate \nthese vulnerabilities. Users of the affected products are encouraged to \ncontact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://electrolink.com/contacts/\"\u003eElectrolink\u003c/a\u003e for additional information.\n\n\u003cbr\u003e"
}
],
"value": "Electrolink has not responded to requests to work with CISA to mitigate \nthese vulnerabilities. Users of the affected products are encouraged to \ncontact Electrolink https://electrolink.com/contacts/ for additional information."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-3742",
"datePublished": "2024-04-18T22:15:35.521Z",
"dateReserved": "2024-04-12T19:46:39.173Z",
"dateUpdated": "2024-08-01T20:20:00.923Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:20:00.923Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-3742\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-07T15:38:32.607032Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:electrolink:medium_dab_transmitter:*:*:*:*:*:*:*:*\"], \"vendor\": \"electrolink\", \"product\": \"medium dab transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"2kW, 1kW, 500W\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:electrolink:digital_fm_transmitter:*:*:*:*:*:*:*:*\"], \"vendor\": \"electrolink\", \"product\": \"digital fm transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"15W\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:electrolink:vhf_tv_transmitter:*:*:*:*:*:*:*:*\"], \"vendor\": \"electrolink\", \"product\": \"vhf tv transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"BI\"}, {\"status\": \"affected\", \"version\": \"BIII\"}, {\"status\": \"affected\", \"version\": \"10W\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:electrolink:high_power_dab_transmitter:*:*:*:*:*:*:*:*\"], \"vendor\": \"electrolink\", \"product\": \"high power dab transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"5kW\"}, {\"status\": \"affected\", \"version\": \"4kW\"}, {\"status\": \"affected\", \"version\": \"3kW\"}, {\"status\": \"affected\", \"version\": \"2.5kW\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:electrolink:compact_dab_transmitter:*:*:*:*:*:*:*:*\"], \"vendor\": \"electrolink\", \"product\": \"compact dab transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"10W\"}, {\"status\": \"affected\", \"version\": \"100W\"}, {\"status\": \"affected\", \"version\": \"250W\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:electrolink:modular_fm_transmitter:*:*:*:*:*:*:*:*\"], \"vendor\": \"electrolink\", \"product\": \"modular fm transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"3kW\"}, {\"status\": \"affected\", \"version\": \"5kW\"}, {\"status\": \"affected\", \"version\": \"10kW\"}, {\"status\": \"affected\", \"version\": \"15kW\"}, {\"status\": \"affected\", \"version\": \"20kW\"}, {\"status\": \"affected\", \"version\": \"30kW\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:electrolink:compact_fm_transmitter:*:*:*:*:*:*:*:*\"], \"vendor\": \"electrolink\", \"product\": \"compact fm transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"500W\"}, {\"status\": \"affected\", \"version\": \"1kW\"}, {\"status\": \"affected\", \"version\": \"2kW\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-07T15:45:47.250Z\"}}], \"cna\": {\"title\": \"Electrolink FM/DAB/TV Transmitter Cleartext Storage of Sensitive Information\", \"source\": {\"advisory\": \"ICSA-24-107-02\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Gjoko Krstic publicly reported these vulnerabilities on the internet after an unsuccessful attempt to contact Electrolink directly.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Electrolink\", \"product\": \"Compact DAB Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"10W\"}, {\"status\": \"affected\", \"version\": \"100W\"}, {\"status\": \"affected\", \"version\": \"250W\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Electrolink\", \"product\": \"Medium DAB Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"500W\"}, {\"status\": \"affected\", \"version\": \"1kW\"}, {\"status\": \"affected\", \"version\": \"2kW\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Electrolink\", \"product\": \"High Power DAB Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.5kW\"}, {\"status\": \"affected\", \"version\": \"3kW\"}, {\"status\": \"affected\", \"version\": \"4kW\"}, {\"status\": \"affected\", \"version\": \"5kW\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Electrolink\", \"product\": \"Compact FM Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"Compact FM Transmitter\"}, {\"status\": \"affected\", \"version\": \"500W\"}, {\"status\": \"affected\", \"version\": \"1kW\"}, {\"status\": \"affected\", \"version\": \"2kW\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Electrolink\", \"product\": \"Modular FM Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"3kW\"}, {\"status\": \"affected\", \"version\": \"5kW\"}, {\"status\": \"affected\", \"version\": \"10kW\"}, {\"status\": \"affected\", \"version\": \"15kW\"}, {\"status\": \"affected\", \"version\": \"20kW\"}, {\"status\": \"affected\", \"version\": \"30kW\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Electrolink\", \"product\": \"Digital FM Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"15W\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"40kW\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Electrolink\", \"product\": \"VHF TV Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"BI\"}, {\"status\": \"affected\", \"version\": \"BIII\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Electrolink\", \"product\": \"UHF TV Transmitter\", \"versions\": [{\"status\": \"affected\", \"version\": \"10W\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"5kW\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Electrolink has not responded to requests to work with CISA to mitigate \\nthese vulnerabilities. Users of the affected products are encouraged to \\ncontact Electrolink https://electrolink.com/contacts/ for additional information.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Electrolink has not responded to requests to work with CISA to mitigate \\nthese vulnerabilities. Users of the affected products are encouraged to \\ncontact \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://electrolink.com/contacts/\\\"\u003eElectrolink\u003c/a\u003e for additional information.\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-312\", \"description\": \"CWE-312 Cleartext Storage of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2024-05-28T16:52:22.524Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-3742\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T20:20:00.923Z\", \"dateReserved\": \"2024-04-12T19:46:39.173Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2024-04-18T22:15:35.521Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…