CVE-2024-37140 (GCVE-0-2024-37140)
Vulnerability from cvelistv5
Published
2024-06-26 03:54
Modified
2024-08-02 03:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application's underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Version: 7.0 ≤ 7.13 Version: N/A ≤ Version: N/A ≤ |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "powerprotect_dd",
"vendor": "dell",
"versions": [
{
"lessThanOrEqual": "7.13",
"status": "affected",
"version": "7.0",
"versionType": "semver"
},
{
"lessThan": "2.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "5.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37140",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-26T14:38:33.257609Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-26T14:49:39.900Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:50:54.530Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "7.13",
"status": "affected",
"version": "7.0",
"versionType": "semver"
},
{
"lessThan": "2.7.7",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5.16.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-06-24T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker."
}
],
"value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-26T03:54:38.461Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-37140",
"datePublished": "2024-06-26T03:54:38.461Z",
"dateReserved": "2024-06-03T12:10:32.206Z",
"dateUpdated": "2024-08-02T03:50:54.530Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T03:50:54.530Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-37140\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-26T14:38:33.257609Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*\"], \"vendor\": \"dell\", \"product\": \"powerprotect_dd\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-26T14:49:34.164Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerProtect DD\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-06-24T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-06-26T03:54:38.461Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-37140\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T03:50:54.530Z\", \"dateReserved\": \"2024-06-03T12:10:32.206Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-06-26T03:54:38.461Z\", \"assignerShortName\": \"dell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…