CVE-2024-34750 (GCVE-0-2024-34750)
Vulnerability from cvelistv5
Published
2024-07-03 19:32
Modified
2025-11-03 19:29
Severity ?
CWE
  • CWE-755 - Improper Handling of Exceptional Conditions
  • CWE-400 - Uncontrolled Resource Consumption
Summary
Improper Handling of Exceptional Conditions, Uncontrolled Resource Consumption vulnerability in Apache Tomcat. When processing an HTTP/2 stream, Tomcat did not handle some cases of excessive HTTP headers correctly. This led to a miscounting of active HTTP/2 streams which in turn led to the use of an incorrect infinite timeout which allowed connections to remain open which should have been closed. This issue affects Apache Tomcat: from 11.0.0-M1 through 11.0.0-M20, from 10.1.0-M1 through 10.1.24, from 9.0.0-M1 through 9.0.89. The following versions were EOL at the time the CVE was created but are known to be affected: 8.5.0 though 8.5.100. Other EOL versions may also be affected. Users are recommended to upgrade to version 11.0.0-M21, 10.1.25 or 9.0.90, which fixes the issue.
Impacted products
Vendor Product Version
Apache Software Foundation Apache Tomcat Version: 11.0.0-M1    11.0.0-M20
Version: 10.1.0-M1    10.1.24
Version: 9.0.0-M1    9.0.89
Version: 8.5.0    8.5.100
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:apache:tomcat:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "tomcat",
            "vendor": "apache",
            "versions": [
              {
                "lessThanOrEqual": "9.0.89",
                "status": "affected",
                "version": "9.0.0-m1",
                "versionType": "semver"
              },
              {
                "lessThanOrEqual": "10.1.24",
                "status": "affected",
                "version": "10.1.0-m1",
                "versionType": "semver"
              },
              {
                "lessThanOrEqual": "11.0.0-m20",
                "status": "affected",
                "version": "11.0.0-m1",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-34750",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T16:51:20.954347Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-13T16:05:56.107Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:29:53.932Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://lists.apache.org/thread/4kqf0bc9gxymjc2x7v3p7dvplnl77y8l"
          },
          {
            "url": "https://security.netapp.com/advisory/ntap-20240816-0004/"
          },
          {
            "url": "https://lists.debian.org/debian-lts-announce/2025/07/msg00009.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Apache Tomcat",
          "vendor": "Apache Software Foundation",
          "versions": [
            {
              "lessThanOrEqual": "11.0.0-M20",
              "status": "affected",
              "version": "11.0.0-M1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "10.1.24",
              "status": "affected",
              "version": "10.1.0-M1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "9.0.89",
              "status": "affected",
              "version": "9.0.0-M1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "8.5.100",
              "status": "affected",
              "version": "8.5.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "10.0.27",
              "status": "unknown",
              "version": "10.0.0-M1",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "devme4f from VNPT-VCI"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eImproper Handling of Exceptional Conditions, Uncontrolled Resource Consumption vulnerability in Apache Tomcat. When processing an HTTP/2 stream, Tomcat did not handle some cases of excessive HTTP headers correctly. This led to a miscounting of active HTTP/2 streams which in turn led to the use of an incorrect infinite timeout which allowed connections to remain open which should have been closed.\u003c/p\u003e\u003cp\u003eThis issue affects Apache Tomcat: from 11.0.0-M1 through 11.0.0-M20, from 10.1.0-M1 through 10.1.24, from 9.0.0-M1 through 9.0.89.\u003c/p\u003e\u003cp\u003eThe following versions were EOL at the time the CVE was created but are \nknown to be affected: 8.5.0 though 8.5.100.\u0026nbsp;Other EOL versions may also be affected.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers are recommended to upgrade to version 11.0.0-M21, 10.1.25 or 9.0.90, which fixes the issue.\u003c/p\u003e"
            }
          ],
          "value": "Improper Handling of Exceptional Conditions, Uncontrolled Resource Consumption vulnerability in Apache Tomcat. When processing an HTTP/2 stream, Tomcat did not handle some cases of excessive HTTP headers correctly. This led to a miscounting of active HTTP/2 streams which in turn led to the use of an incorrect infinite timeout which allowed connections to remain open which should have been closed.\n\nThis issue affects Apache Tomcat: from 11.0.0-M1 through 11.0.0-M20, from 10.1.0-M1 through 10.1.24, from 9.0.0-M1 through 9.0.89.\n\nThe following versions were EOL at the time the CVE was created but are \nknown to be affected: 8.5.0 though 8.5.100.\u00a0Other EOL versions may also be affected.\n\n\nUsers are recommended to upgrade to version 11.0.0-M21, 10.1.25 or 9.0.90, which fixes the issue."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "text": "important"
            },
            "type": "Textual description of severity"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-755",
              "description": "CWE-755 Improper Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-29T11:55:38.977Z",
        "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "shortName": "apache"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.apache.org/thread/4kqf0bc9gxymjc2x7v3p7dvplnl77y8l"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Apache Tomcat: HTTP/2 excess header handling DoS",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
    "assignerShortName": "apache",
    "cveId": "CVE-2024-34750",
    "datePublished": "2024-07-03T19:32:34.695Z",
    "dateReserved": "2024-05-08T07:23:16.760Z",
    "dateUpdated": "2025-11-03T19:29:53.932Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…