CVE-2024-33509 (GCVE-0-2024-33509)
Vulnerability from cvelistv5
Published
2024-07-09 15:33
Modified
2024-08-02 02:36
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-295 - Information disclosure
Summary
An improper certificate validation vulnerability [CWE-295] in FortiWeb 7.2.0 through 7.2.1, 7.0 all versions, 6.4 all versions and 6.3 all versions may allow a remote and unauthenticated attacker in a Man-in-the-Middle position to decipher and/or tamper with the communication channel between the device and different endpoints used to fetch data for Web Application Firewall (WAF).
References
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fortiweb",
"vendor": "fortinet",
"versions": [
{
"status": "affected",
"version": "7.2.0"
},
{
"status": "affected",
"version": "7.0.0"
},
{
"status": "affected",
"version": "6.4.0"
},
{
"status": "affected",
"version": "6.3.0"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33509",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T15:48:02.416435Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T15:04:39.003Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:36:02.831Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://fortiguard.fortinet.com/psirt/FG-IR-22-326",
"tags": [
"x_transferred"
],
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-22-326"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FortiWeb",
"vendor": "Fortinet",
"versions": [
{
"lessThanOrEqual": "7.2.1",
"status": "affected",
"version": "7.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.0.10",
"status": "affected",
"version": "7.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.4.3",
"status": "affected",
"version": "6.4.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.3.23",
"status": "affected",
"version": "6.3.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper certificate validation vulnerability [CWE-295] in FortiWeb 7.2.0 through 7.2.1, 7.0 all versions, 6.4 all versions and 6.3 all versions may allow a remote and unauthenticated attacker in a Man-in-the-Middle position to decipher and/or tamper with the communication channel between the device and different endpoints used to fetch data for Web Application Firewall (WAF)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N/E:U/RL:O/RC:R",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "Information disclosure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T15:33:24.418Z",
"orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"shortName": "fortinet"
},
"references": [
{
"name": "https://fortiguard.fortinet.com/psirt/FG-IR-22-326",
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-22-326"
}
],
"solutions": [
{
"lang": "en",
"value": "Please upgrade to FortiWeb version 7.2.2 or above \n"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"assignerShortName": "fortinet",
"cveId": "CVE-2024-33509",
"datePublished": "2024-07-09T15:33:24.418Z",
"dateReserved": "2024-04-23T14:18:29.831Z",
"dateUpdated": "2024-08-02T02:36:02.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…