CVE-2024-22439 (GCVE-0-2024-22439)
Vulnerability from cvelistv5
Published
2024-04-15 10:08
Modified
2024-08-01 22:43
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Summary
A potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.
Impacted products
Vendor Product Version
Hewlett Packard Enterprise HPE FlexNetwork and FlexFabric products Version: See security bulletin HPESBNW04625 for details
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22439",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-17T20:21:10.000927Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:52:46.976Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "platforms": [
            "Custom"
          ],
          "product": "HPE FlexNetwork and FlexFabric products",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "See security bulletin HPESBNW04625 for details"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Zhuo Zixiao and Alwen Tiu of Australian National University (ANU)"
        }
      ],
      "datePublic": "2024-04-11T09:59:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-15T10:08:57.234Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
        }
      ],
      "source": {
        "advisory": "HPESBNW04625",
        "discovery": "UNKNOWN"
      },
      "title": "Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2024-22439",
    "datePublished": "2024-04-15T10:08:57.234Z",
    "dateReserved": "2024-01-10T15:24:39.967Z",
    "dateUpdated": "2024-08-01T22:43:34.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T22:43:34.952Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-22439\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-04-17T20:21:10.000927Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-23T19:01:23.838Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass\", \"source\": {\"advisory\": \"HPESBNW04625\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Zhuo Zixiao and Alwen Tiu of Australian National University (ANU)\"}], \"impacts\": [{\"capecId\": \"CAPEC-233\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-233 Privilege Escalation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 6.9, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hewlett Packard Enterprise\", \"product\": \"HPE FlexNetwork and FlexFabric products\", \"versions\": [{\"status\": \"affected\", \"version\": \"See security bulletin HPESBNW04625 for details\"}], \"platforms\": [\"Custom\"], \"defaultStatus\": \"affected\"}], \"datePublic\": \"2024-04-11T09:59:00.000Z\", \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-639\", \"description\": \"CWE-639 Authorization Bypass Through User-Controlled Key\"}]}], \"providerMetadata\": {\"orgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"shortName\": \"hpe\", \"dateUpdated\": \"2024-04-15T10:08:57.234Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-22439\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T22:43:34.952Z\", \"dateReserved\": \"2024-01-10T15:24:39.967Z\", \"assignerOrgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"datePublished\": \"2024-04-15T10:08:57.234Z\", \"assignerShortName\": \"hpe\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…