CVE-2024-21916 (GCVE-0-2024-21916)
Vulnerability from cvelistv5
Published
2024-01-31 18:28
Modified
2024-08-01 22:35
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "controllogix_5570_controller_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "20.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "guardlogix_5570_controller_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "20.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "controllogix_5570_redundant_controller_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "20.054_kit1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-21916",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-06T05:00:32.025684Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-01T19:54:41.466Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.618Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5570",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "20.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GuardLogix\u00ae 5570",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "20.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5570 redundant",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "20.054_kit1"
            }
          ]
        }
      ],
      "datePublic": "2024-01-30T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMNRF.\u003c/a\u003e"
            }
          ],
          "value": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-31T18:28:59.715Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cul\u003e\u003cli\u003eUpdate to corrected Firmware.\u0026nbsp;\u003c/li\u003e\u003c/ul\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAffected Product\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eFirst Known in Firmware\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in Firmware\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix\u00ae 5570\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570 redundant\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.054_kit1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n  *  Update to corrected Firmware.\u00a0\n\n\n\n\nAffected Product\n\nFirst Known in Firmware\n\nCorrected in Firmware\n\nControlLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nGuardLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nControlLogix\u00ae 5570 redundant\n\n20.054_kit1\n\nv33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\n\n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-21916",
    "datePublished": "2024-01-31T18:28:59.715Z",
    "dateReserved": "2024-01-03T16:40:50.367Z",
    "dateUpdated": "2024-08-01T22:35:34.618Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T22:35:34.618Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-21916\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-02-06T05:00:32.025684Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"controllogix_5570_controller_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"20.011\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"guardlogix_5570_controller_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"20.011\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"controllogix_5570_redundant_controller_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"20.054_kit1\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-01T19:53:42.020Z\"}}], \"cna\": {\"title\": \"Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-100\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-100 Overflow Buffers\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"ControlLogix\\u00ae 5570\", \"versions\": [{\"status\": \"affected\", \"version\": \"20.011\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"GuardLogix\\u00ae 5570\", \"versions\": [{\"status\": \"affected\", \"version\": \"20.011\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"ControlLogix\\u00ae 5570 redundant\", \"versions\": [{\"status\": \"affected\", \"version\": \"20.054_kit1\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"\\n  *  Update to corrected Firmware.\\u00a0\\n\\n\\n\\n\\nAffected Product\\n\\nFirst Known in Firmware\\n\\nCorrected in Firmware\\n\\nControlLogix\\u00ae 5570\\n\\n20.011\\n\\nv33.016, 34.013, 35.012, 36.011 and later\\n\\nGuardLogix\\u00ae 5570\\n\\n20.011\\n\\nv33.016, 34.013, 35.012, 36.011 and later\\n\\nControlLogix\\u00ae 5570 redundant\\n\\n20.054_kit1\\n\\nv33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\\n\\n\\n\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cul\u003e\u003cli\u003eUpdate to corrected Firmware.\u0026nbsp;\u003c/li\u003e\u003c/ul\u003e\\n\\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eAffected Product\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eFirst Known in Firmware\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in Firmware\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\\u00ae 5570\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix\\u00ae 5570\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\\u00ae 5570 redundant\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.054_kit1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\\n\\n\u003cbr\u003e\\n\\n\", \"base64\": false}]}], \"datePublic\": \"2024-01-30T14:00:00.000Z\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the \u003c/span\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eMNRF.\u003c/a\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2024-01-31T18:28:59.715Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-21916\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T22:35:34.618Z\", \"dateReserved\": \"2024-01-03T16:40:50.367Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2024-01-31T18:28:59.715Z\", \"assignerShortName\": \"Rockwell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…