CVE-2024-1574 (GCVE-0-2024-1574)
Vulnerability from cvelistv5
Published
2024-07-04 09:02
Modified
2026-04-08 13:31
CWE
  • CWE-470 - Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')
Summary
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.
Impacted products
Vendor Product Version
Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation GENESIS64 Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation ICONICS Suite Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Iconics Digital Solutions Hyper Historian Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation Hyper Historian Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Iconics Digital Solutions AnalytiX Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation AnalytiX Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Iconics Digital Solutions MobileHMI Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation MobileHMI Version: versions 10.97.2 and prior
Create a notification for this product.
   Mitsubishi Electric Iconics Digital Solutions GENESIS32 Version: versions 9.7 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation GENESIS32 Version: versions 9.7 and prior
Create a notification for this product.
   Mitsubishi Electric Iconics Digital Solutions BizViz Version: versions 9.7 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation BizViz Version: versions 9.7 and prior
Create a notification for this product.
   Mitsubishi Electric Corporation MC Works64 Version: all versions
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "genesis64",
            "vendor": "iconics",
            "versions": [
              {
                "lessThan": "10.97.92",
                "status": "affected",
                "version": "10.97",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mc_works64",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-1574",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-05T14:44:19.238774Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T14:45:36.502Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:40:21.447Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU98894016/"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS64",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS64",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICONICS Suite",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICONICS Suite",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Hyper Historian",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Hyper Historian",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AnalytiX",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AnalytiX",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MobileHMI",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MobileHMI",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.2 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS32",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 9.7 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS32",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 9.7 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BizViz",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 9.7 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BizViz",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 9.7 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MC Works64",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.\u0026nbsp;\u003cbr\u003e"
            }
          ],
          "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Malicious Code Execution"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-470",
              "description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-08T13:31:05.753Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU98894016/"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2024-1574",
    "datePublished": "2024-07-04T09:02:35.260Z",
    "dateReserved": "2024-02-16T01:30:45.960Z",
    "dateUpdated": "2026-04-08T13:31:05.753Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU98894016/\", \"tags\": [\"government-resource\", \"x_transferred\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03\", \"tags\": [\"government-resource\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T18:40:21.447Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-1574\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-05T14:44:19.238774Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*\"], \"vendor\": \"iconics\", \"product\": \"genesis64\", \"versions\": [{\"status\": \"affected\", \"version\": \"10.97\", \"lessThan\": \"10.97.92\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*\"], \"vendor\": \"mitsubishielectric\", \"product\": \"mc_works64\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"unaffected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-05T14:44:09.206Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"Malicious Code Execution\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.7, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Mitsubishi Electric Iconics Digital Solutions\", \"product\": \"GENESIS64\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GENESIS64\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Iconics Digital Solutions\", \"product\": \"ICONICS Suite\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"ICONICS Suite\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Iconics Digital Solutions\", \"product\": \"Hyper Historian\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Hyper Historian\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Iconics Digital Solutions\", \"product\": \"AnalytiX\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"AnalytiX\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Iconics Digital Solutions\", \"product\": \"MobileHMI\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MobileHMI\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 10.97.2 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Iconics Digital Solutions\", \"product\": \"GENESIS32\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 9.7 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GENESIS32\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 9.7 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Iconics Digital Solutions\", \"product\": \"BizViz\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 9.7 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"BizViz\", \"versions\": [{\"status\": \"affected\", \"version\": \"versions 9.7 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MC Works64\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU98894016/\", \"tags\": [\"government-resource\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric BizViz versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions BizViz versions 9.7 and prior allows a local attacker to execute a malicious code with administrative privileges by tampering with a specific file that is not protected by the system.\u0026nbsp;\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-470\", \"description\": \"CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"shortName\": \"Mitsubishi\", \"dateUpdated\": \"2026-04-08T13:31:05.753Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-1574\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-08T13:31:05.753Z\", \"dateReserved\": \"2024-02-16T01:30:45.960Z\", \"assignerOrgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"datePublished\": \"2024-07-04T09:02:35.260Z\", \"assignerShortName\": \"Mitsubishi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…