CVE-2023-6943 (GCVE-0-2023-6943)
Vulnerability from cvelistv5
Published
2024-01-30 09:09
Modified
2025-09-19 02:13
Severity ?
CWE
  • CWE-470 - Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')
Summary
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:42:08.552Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU95103362"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6943",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-06T05:00:32.912521Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-30T19:01:43.512Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EZSocket",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "3.0 to 5.92"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT1000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.325P and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT2000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.320J and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.11M to 1.626C"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.106L and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.04E to 2.102G"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MT Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.190Y and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Component",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "4.00A to 5.007H"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX OPC Server DA/UA",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."
            }
          ],
          "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Remote Code Execution"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-470",
              "description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-19T02:13:47.115Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU95103362"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-6943",
    "datePublished": "2024-01-30T09:09:29.248Z",
    "dateReserved": "2023-12-19T08:00:07.140Z",
    "dateUpdated": "2025-09-19T02:13:47.115Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU95103362\", \"tags\": [\"government-resource\", \"x_transferred\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02\", \"tags\": [\"government-resource\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T08:42:08.552Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-6943\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-02-06T05:00:32.912521Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-30T19:01:39.589Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"Remote Code Execution\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"EZSocket\", \"versions\": [{\"status\": \"affected\", \"version\": \"3.0 to 5.92\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GT Designer3 Version1(GOT1000)\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.325P and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GT Designer3 Version1(GOT2000)\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.320J and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GX Works2\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.11M to 1.626C\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GX Works3\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.106L and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MELSOFT Navigator\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.04E to 2.102G\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MT Works2\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.190Y and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MX Component\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.00A to 5.007H\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MX OPC Server DA/UA\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU95103362\", \"tags\": [\"government-resource\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-470\", \"description\": \"CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"shortName\": \"Mitsubishi\", \"dateUpdated\": \"2025-09-19T02:13:47.115Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-6943\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-19T02:13:47.115Z\", \"dateReserved\": \"2023-12-19T08:00:07.140Z\", \"assignerOrgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"datePublished\": \"2024-01-30T09:09:29.248Z\", \"assignerShortName\": \"Mitsubishi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…