CVE-2023-5768 (GCVE-0-2023-5768)
Vulnerability from cvelistv5
Published
2023-12-04 14:33
Modified
2024-08-02 08:07
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below.
Incomplete or wrong received APDU frame layout may
cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer
with wrong length information of APDU or delayed reception
of data octets.
Only communication link of affected HCI IEC 60870-5-104
is blocked. If attack sequence stops the communication to
the previously attacked link gets normal again.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hitachi Energy | RTU500 series |
Version: RTU500 series CMU Firmware version 12.0.1 – 12.0.14 Version: RTU500 series CMU Firmware version 12.2.1 – 12.2.11 Version: RTU500 series CMU Firmware version 12.4.1 – 12.4.11 Version: RTU500 series CMU Firmware version 12.6.1 – 12.6.9 Version: RTU500 series CMU Firmware version 12.7.1 – 12.7.6 Version: RTU500 series CMU Firmware version 13.2.1 – 13.2.6 Version: RTU500 series CMU Firmware version 13.4.1 – 13.4.3 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:07:32.849Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.0.1 \u2013 12.0.14"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.2.1 \u2013 12.2.11"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.4.1 \u2013 12.4.11 "
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.6.1 \u2013 12.6.9 "
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 12.7.1 \u2013 12.7.6"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.2.1 \u2013 13.2.6 "
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.4.1 \u2013 13.4.3 "
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\u003cbr\u003e\u003cbr\u003eOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n"
}
],
"value": "A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. \nIncomplete or wrong received APDU frame layout may \ncause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer \nwith wrong length information of APDU or delayed reception \nof data octets.\n\n\nOnly communication link of affected HCI IEC 60870-5-104 \nis blocked. If attack sequence stops the communication to \nthe previously attacked link gets normal again.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-04T14:35:49.612Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2023-5768",
"datePublished": "2023-12-04T14:33:47.898Z",
"dateReserved": "2023-10-25T15:24:39.183Z",
"dateUpdated": "2024-08-02T08:07:32.849Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…