CVE-2023-5746 (GCVE-0-2023-5746)
Vulnerability from cvelistv5
Published
2023-10-24 07:32
Modified
2024-09-12 14:33
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability regarding use of externally-controlled format string is found in the cgi component. This allows remote attackers to execute arbitrary code via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.5-0185 may be affected: BC500 and TC500.
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Synology | Camera Firmware |
Version: 1.0 ≤ |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:07:32.655Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "Synology-SA-23:11 Synology Camera",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_23_11"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:synology:camera_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "camera_firmware",
"vendor": "synology",
"versions": [
{
"lessThan": "1.0.5-0185",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T20:00:45.716483Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:33:52.546Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"platforms": [
"BC500",
"TC500"
],
"product": "Camera Firmware",
"vendor": "Synology",
"versions": [
{
"lessThan": "1.0.5-0185",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "chumen77(GAO JUYANG) from WeBin Lab of DbappSecurity Co.,Ltd."
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability regarding use of externally-controlled format string is found in the cgi component. This allows remote attackers to execute arbitrary code via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.5-0185 may be affected: BC500 and TC500."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-24T10:24:05.921Z",
"orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"shortName": "synology"
},
"references": [
{
"name": "Synology-SA-23:11 Synology Camera",
"tags": [
"vendor-advisory"
],
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_23_11"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"assignerShortName": "synology",
"cveId": "CVE-2023-5746",
"datePublished": "2023-10-24T07:32:14.184Z",
"dateReserved": "2023-10-24T02:48:16.801Z",
"dateUpdated": "2024-09-12T14:33:52.546Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.synology.com/en-global/security/advisory/Synology_SA_23_11\", \"name\": \"Synology-SA-23:11 Synology Camera\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T08:07:32.655Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-5746\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-09T20:00:45.716483Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:synology:camera_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"synology\", \"product\": \"camera_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.5-0185\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-09T20:00:19.868Z\"}}], \"cna\": {\"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"chumen77(GAO JUYANG) from WeBin Lab of DbappSecurity Co.,Ltd.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Synology\", \"product\": \"Camera Firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0\", \"lessThan\": \"1.0.5-0185\", \"versionType\": \"semver\"}], \"platforms\": [\"BC500\", \"TC500\"], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://www.synology.com/en-global/security/advisory/Synology_SA_23_11\", \"name\": \"Synology-SA-23:11 Synology Camera\", \"tags\": [\"vendor-advisory\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability regarding use of externally-controlled format string is found in the cgi component. This allows remote attackers to execute arbitrary code via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.5-0185 may be affected: BC500 and TC500.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-134: Use of Externally-Controlled Format String\"}]}], \"providerMetadata\": {\"orgId\": \"db201096-a0cc-46c7-9a55-61d9e221bf01\", \"shortName\": \"synology\", \"dateUpdated\": \"2023-10-24T10:24:05.921Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-5746\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-12T14:33:52.546Z\", \"dateReserved\": \"2023-10-24T02:48:16.801Z\", \"assignerOrgId\": \"db201096-a0cc-46c7-9a55-61d9e221bf01\", \"datePublished\": \"2023-10-24T07:32:14.184Z\", \"assignerShortName\": \"synology\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…