CVE-2023-5326 (GCVE-0-2023-5326)
Vulnerability from cvelistv5
Published
2023-10-01 22:00
Modified
2024-09-20 16:21
CWE
  • CWE-287 - Improper Authentication
Summary
A vulnerability was found in SATO CL4NX-J Plus 1.13.2-u455_r2. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component WebConfig. The manipulation leads to improper authentication. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-241027.
References
Impacted products
Vendor Product Version
SATO CL4NX-J Plus Version: 1.13.2-u455_r2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:52:08.573Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.241027"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.241027"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus/README.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-5326",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-20T16:21:27.208497Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-20T16:21:50.811Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "WebConfig"
          ],
          "product": "CL4NX-J Plus",
          "vendor": "SATO",
          "versions": [
            {
              "status": "affected",
              "version": "1.13.2-u455_r2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "CV3TR4CK (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in SATO CL4NX-J Plus 1.13.2-u455_r2. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component WebConfig. The manipulation leads to improper authentication. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-241027."
        },
        {
          "lang": "de",
          "value": "In SATO CL4NX-J Plus 1.13.2-u455_r2 wurde eine kritische Schwachstelle ausgemacht. Betroffen ist eine unbekannte Verarbeitung der Komponente WebConfig. Mittels Manipulieren mit unbekannten Daten kann eine improper authentication-Schwachstelle ausgenutzt werden. Der Angriff kann im lokalen Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-25T05:09:09.735Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.241027"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.241027"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus/README.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-10-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-10-01T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-10-01T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-10-23T08:14:56.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "SATO CL4NX-J Plus WebConfig improper authentication"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-5326",
    "datePublished": "2023-10-01T22:00:08.112Z",
    "dateReserved": "2023-10-01T12:10:13.678Z",
    "dateUpdated": "2024-09-20T16:21:50.811Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.241027\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.241027\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus/README.md\", \"tags\": [\"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T07:52:08.573Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-5326\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-20T16:21:27.208497Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-20T16:21:47.219Z\"}}], \"cna\": {\"title\": \"SATO CL4NX-J Plus WebConfig improper authentication\", \"credits\": [{\"lang\": \"en\", \"type\": \"analyst\", \"value\": \"CV3TR4CK (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 5.8, \"vectorString\": \"AV:A/AC:L/Au:N/C:P/I:P/A:P\"}}], \"affected\": [{\"vendor\": \"SATO\", \"modules\": [\"WebConfig\"], \"product\": \"CL4NX-J Plus\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.13.2-u455_r2\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2023-10-01T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2023-10-01T00:00:00.000Z\", \"value\": \"CVE reserved\"}, {\"lang\": \"en\", \"time\": \"2023-10-01T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2023-10-23T08:14:56.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.241027\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.241027\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus/README.md\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in SATO CL4NX-J Plus 1.13.2-u455_r2. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component WebConfig. The manipulation leads to improper authentication. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-241027.\"}, {\"lang\": \"de\", \"value\": \"In SATO CL4NX-J Plus 1.13.2-u455_r2 wurde eine kritische Schwachstelle ausgemacht. Betroffen ist eine unbekannte Verarbeitung der Komponente WebConfig. Mittels Manipulieren mit unbekannten Daten kann eine improper authentication-Schwachstelle ausgenutzt werden. Der Angriff kann im lokalen Netzwerk passieren. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-287\", \"description\": \"CWE-287 Improper Authentication\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2023-10-25T05:09:09.735Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-5326\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-20T16:21:50.811Z\", \"dateReserved\": \"2023-10-01T12:10:13.678Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2023-10-01T22:00:08.112Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…