CVE-2023-4816 (GCVE-0-2023-4816)

Vulnerability from cvelistv5 – Published: 2023-09-11 07:40 – Updated: 2024-09-25 20:01
VLAI
Summary
A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-25 16:17 UTC
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
Hitachi Energy Asset Suite 9 Affected: 9.6.3.11.0 , ≤ 9.6.3.11.1 (custom)
Affected: 9.6.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:38:00.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4816",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-25T16:17:59.131708Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-25T20:01:08.623Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Asset Suite 9",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "9.6.3.11.1",
              "status": "affected",
              "version": "9.6.3.11.0",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "9.6.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action."
            }
          ],
          "value": "A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-114",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-114 Authentication Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-01T01:53:57.383Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "url": "https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2023-4816",
    "datePublished": "2023-09-11T07:40:46.735Z",
    "dateReserved": "2023-09-07T07:02:56.867Z",
    "dateUpdated": "2024-09-25T20:01:08.623Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:38:00.641Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-4816",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-25T16:17:59.131708Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-25T20:00:59.990Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Asset Suite 9",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "9.6.3.11.1",
                  "status": "affected",
                  "version": "9.6.3.11.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "9.6.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action."
                }
              ],
              "value": "A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-114",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-114 Authentication Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-01T01:53:57.383Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://images.go.hitachienergy.com/Web/ABBEnterpriseSoftware/%7B70b3d323-4866-42e1-8a75-58996729c1d4%7D_8DBD000172-VU-2023-23_Asset_Suite_Tagout_vulnerability_Rev1.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2023-4816",
        "datePublished": "2023-09-11T07:40:46.735Z",
        "dateReserved": "2023-09-07T07:02:56.867Z",
        "dateUpdated": "2024-09-25T20:01:08.623Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.