CVE-2023-4414 (GCVE-0-2023-4414)
Vulnerability from cvelistv5
Published
2023-08-18 16:00
Modified
2024-11-21 14:58
CWE
Summary
A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230807. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-237517 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
https://vuldb.com/?id.237517 vdb-entry, technical-description
https://vuldb.com/?ctiid.237517 signature, permissions-required
https://vuldb.com/?submit.191743 third-party-advisory
https://github.com/RCEraser/cve/blob/main/S85F.md exploit
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:24:04.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-237517 | Byzoro Smart S85F Management Platform decodmail.php command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.237517"
          },
          {
            "name": "VDB-237517 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.237517"
          },
          {
            "name": "Submit #191743 | The Smart S85F management platform has an rce vulnerability",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.191743"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/RCEraser/cve/blob/main/S85F.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4414",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T14:57:34.036095Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T14:58:33.583Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart S85F Management Platform",
          "vendor": "Byzoro",
          "versions": [
            {
              "status": "affected",
              "version": "20230807"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "RCEraser (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230807. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-237517 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Byzoro Smart S85F Management Platform bis 20230807 wurde eine kritische Schwachstelle ausgemacht. Betroffen ist eine unbekannte Verarbeitung der Datei /log/decodmail.php. Mittels dem Manipulieren des Arguments file mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-09T08:34:40.086Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-237517 | Byzoro Smart S85F Management Platform decodmail.php command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.237517"
        },
        {
          "name": "VDB-237517 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.237517"
        },
        {
          "name": "Submit #191743 | The Smart S85F management platform has an rce vulnerability",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.191743"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/RCEraser/cve/blob/main/S85F.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-08-18T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-08-18T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-08-18T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-09T09:06:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Byzoro Smart S85F Management Platform decodmail.php command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-4414",
    "datePublished": "2023-08-18T16:00:05.398Z",
    "dateReserved": "2023-08-18T08:15:50.848Z",
    "dateUpdated": "2024-11-21T14:58:33.583Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.237517\", \"name\": \"VDB-237517 | Byzoro Smart S85F Management Platform decodmail.php command injection\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.237517\", \"name\": \"VDB-237517 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?submit.191743\", \"name\": \"Submit #191743 | The Smart S85F management platform has an rce vulnerability\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}, {\"url\": \"https://github.com/RCEraser/cve/blob/main/S85F.md\", \"tags\": [\"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T07:24:04.627Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-4414\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-21T14:57:34.036095Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-21T14:58:30.316Z\"}}], \"cna\": {\"title\": \"Byzoro Smart S85F Management Platform decodmail.php command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"RCEraser (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\"}}], \"affected\": [{\"vendor\": \"Byzoro\", \"product\": \"Smart S85F Management Platform\", \"versions\": [{\"status\": \"affected\", \"version\": \"20230807\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2023-08-18T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2023-08-18T00:00:00.000Z\", \"value\": \"CVE reserved\"}, {\"lang\": \"en\", \"time\": \"2023-08-18T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-04-09T09:06:24.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.237517\", \"name\": \"VDB-237517 | Byzoro Smart S85F Management Platform decodmail.php command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.237517\", \"name\": \"VDB-237517 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.191743\", \"name\": \"Submit #191743 | The Smart S85F management platform has an rce vulnerability\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/RCEraser/cve/blob/main/S85F.md\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230807. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-237517 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"In Byzoro Smart S85F Management Platform bis 20230807 wurde eine kritische Schwachstelle ausgemacht. Betroffen ist eine unbekannte Verarbeitung der Datei /log/decodmail.php. Mittels dem Manipulieren des Arguments file mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk passieren. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-04-09T08:34:40.086Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-4414\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-21T14:58:33.583Z\", \"dateReserved\": \"2023-08-18T08:15:50.848Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2023-08-18T16:00:05.398Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…