CVE-2023-44109 (GCVE-0-2023-44109)
Vulnerability from cvelistv5
Published
2023-10-11 10:41
Modified
2024-08-02 19:59
Severity ?
CWE
  • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Summary
Clone vulnerability in the huks ta module.Successful exploitation of this vulnerability may affect service confidentiality.
Impacted products
Vendor Product Version
Huawei HarmonyOS Version: 4.0.0
Version: 3.1.0
Version: 3.0.0
Version: 2.1.0
Version: 2.0.1
Version: 2.0.0
Create a notification for this product.
   Huawei EMUI Version: 13.0.0
Version: 12.0.1
Version: 12.0.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:59:50.707Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://consumer.huawei.com/en/support/bulletin/2023/10/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://device.harmonyos.com/en/docs/security/update/security-bulletins-202310-0000001663676540"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "HarmonyOS",
          "vendor": "Huawei",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.0"
            },
            {
              "status": "affected",
              "version": "3.1.0"
            },
            {
              "status": "affected",
              "version": "3.0.0"
            },
            {
              "status": "affected",
              "version": "2.1.0"
            },
            {
              "status": "affected",
              "version": "2.0.1"
            },
            {
              "status": "affected",
              "version": "2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EMUI",
          "vendor": "Huawei",
          "versions": [
            {
              "status": "affected",
              "version": "13.0.0"
            },
            {
              "status": "affected",
              "version": "12.0.1"
            },
            {
              "status": "affected",
              "version": "12.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Clone vulnerability in the huks ta module.Successful exploitation of this vulnerability may affect service confidentiality."
            }
          ],
          "value": "Clone vulnerability in the huks ta module.Successful exploitation of this vulnerability may affect service confidentiality."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-11T10:41:47.947Z",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "url": "https://consumer.huawei.com/en/support/bulletin/2023/10/"
        },
        {
          "url": "https://device.harmonyos.com/en/docs/security/update/security-bulletins-202310-0000001663676540"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2023-44109",
    "datePublished": "2023-10-11T10:41:47.947Z",
    "dateReserved": "2023-09-25T09:11:04.625Z",
    "dateUpdated": "2024-08-02T19:59:50.707Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…