CVE-2023-39472 (GCVE-0-2023-39472)
Vulnerability from cvelistv5
Published
2024-05-03 02:10
Modified
2024-08-02 18:10
CWE
  • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
Summary
Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability. The specific flaw exists within the SimpleXMLReader class. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the SYSTEM. . Was ZDI-CAN-17571.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ignition",
            "vendor": "inductiveautomation",
            "versions": [
              {
                "status": "affected",
                "version": "8.1.17 LTS"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-39472",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-10T18:22:51.863259Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:27:10.426Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:10:20.889Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "ZDI-23-1048",
            "tags": [
              "x_research-advisory",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1048/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Ignition",
          "vendor": "Inductive Automation",
          "versions": [
            {
              "status": "affected",
              "version": "8.1.17 LTS"
            }
          ]
        }
      ],
      "dateAssigned": "2023-08-02T16:44:31.483-05:00",
      "datePublic": "2023-08-08T09:49:22.244-05:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the SimpleXMLReader class. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the SYSTEM.\n. Was ZDI-CAN-17571."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-09T22:21:06.255Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-23-1048",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1048/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative"
      },
      "title": "Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2023-39472",
    "datePublished": "2024-05-03T02:10:39.196Z",
    "dateReserved": "2023-08-02T21:37:23.124Z",
    "dateUpdated": "2024-08-02T18:10:20.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-23-1048/\", \"name\": \"ZDI-23-1048\", \"tags\": [\"x_research-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T18:10:20.889Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-39472\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-10T18:22:51.863259Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*\"], \"vendor\": \"inductiveautomation\", \"product\": \"ignition\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.1.17 LTS\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-10T18:26:06.335Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\"}}], \"affected\": [{\"vendor\": \"Inductive Automation\", \"product\": \"Ignition\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.1.17 LTS\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2023-08-08T09:49:22.244-05:00\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-23-1048/\", \"name\": \"ZDI-23-1048\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2023-08-02T16:44:31.483-05:00\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the SimpleXMLReader class. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the SYSTEM.\\n. Was ZDI-CAN-17571.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-611\", \"description\": \"CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2024-05-09T22:21:06.255Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-39472\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T18:10:20.889Z\", \"dateReserved\": \"2023-08-02T21:37:23.124Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2024-05-03T02:10:39.196Z\", \"assignerShortName\": \"zdi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…