CVE-2023-39256 (GCVE-0-2023-39256)
Vulnerability from cvelistv5
Published
2023-12-02 04:18
Modified
2024-08-02 18:02
CWE
  • CWE-284 - Improper Access Control
Summary
Dell Rugged Control Center, version prior to 4.7, contains an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability to modify the content in an unsecured folder during product installation and upgrade, leading to privilege escalation on the system.
Impacted products
Vendor Product Version
Dell Rugged Control Center (RCC) Version: Versions prior to 4.7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:02:06.679Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000217705/dsa-2023-340"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Rugged Control Center (RCC)",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to 4.7"
            }
          ]
        }
      ],
      "datePublic": "2023-11-30T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Rugged Control Center, version prior to 4.7, contains an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability to modify the content in an unsecured folder during product installation and upgrade, leading to privilege escalation on the system.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell Rugged Control Center, version prior to 4.7, contains an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability to modify the content in an unsecured folder during product installation and upgrade, leading to privilege escalation on the system.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-02T04:18:38.674Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000217705/dsa-2023-340"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-39256",
    "datePublished": "2023-12-02T04:18:38.674Z",
    "dateReserved": "2023-07-26T08:15:44.774Z",
    "dateUpdated": "2024-08-02T18:02:06.679Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…