CVE-2023-38255 (GCVE-0-2023-38255)
Vulnerability from cvelistv5
Published
2023-09-18 20:08
Modified
2024-08-02 17:39
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Cross-site Scripting
Summary
A potential attacker with or without (cookie theft) access to the device would be able to include malicious code (XSS) when uploading new device configuration that could affect the intended function of the device.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Socomec | MODULYS GP (MOD3GP-SY-120K) |
Version: v01.12.10 |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:socomec:modulys_gp_firmware:01.12.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modulys_gp_firmware",
"vendor": "socomec",
"versions": [
{
"status": "affected",
"version": "01.12.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38255",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-18T14:46:11.286296Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-18T14:46:47.854Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:39:12.120Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-250-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MODULYS GP (MOD3GP-SY-120K)",
"vendor": "Socomec",
"versions": [
{
"status": "affected",
"version": "v01.12.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Aar\u00f3n Flecha Men\u00e9ndez reported these vulnerabilities to CISA."
}
],
"datePublic": "2023-09-07T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA potential attacker with or without (cookie theft) access to the device would be able to include malicious code (XSS) when uploading new device configuration that could affect the intended function of the device.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
}
],
"value": "\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nA potential attacker with or without (cookie theft) access to the device would be able to include malicious code (XSS) when uploading new device configuration that could affect the intended function of the device.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-18T20:08:05.295Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-250-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSocomec reports that MODULYS GP (MOD3GP-SY-120K) is an End-of-Life product. Socomec recommends using MODULYS GP2 (M4-S-XXX) instead. MODULYS GP2 (M4-S-XXX) is not affected by the above vulnerabilities.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nSocomec reports that MODULYS GP (MOD3GP-SY-120K) is an End-of-Life product. Socomec recommends using MODULYS GP2 (M4-S-XXX) instead. MODULYS GP2 (M4-S-XXX) is not affected by the above vulnerabilities.\n\n\n"
}
],
"source": {
"advisory": "ICSA-23-250-03",
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Socomec MOD3GP-SY-120K Cross-site Scripting",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-38255",
"datePublished": "2023-09-18T20:08:05.295Z",
"dateReserved": "2023-09-06T15:41:16.539Z",
"dateUpdated": "2024-08-02T17:39:12.120Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-250-03\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T17:39:12.120Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-38255\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-18T14:46:11.286296Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:socomec:modulys_gp_firmware:01.12.10:*:*:*:*:*:*:*\"], \"vendor\": \"socomec\", \"product\": \"modulys_gp_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"01.12.10\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-18T14:46:43.480Z\"}}], \"cna\": {\"tags\": [\"unsupported-when-assigned\"], \"title\": \"Socomec MOD3GP-SY-120K Cross-site Scripting\", \"source\": {\"advisory\": \"ICSA-23-250-03\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Aar\\u00f3n Flecha Men\\u00e9ndez reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Socomec\", \"product\": \"MODULYS GP (MOD3GP-SY-120K)\", \"versions\": [{\"status\": \"affected\", \"version\": \"v01.12.10\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"\\nSocomec reports that MODULYS GP (MOD3GP-SY-120K) is an End-of-Life product. Socomec recommends using MODULYS GP2 (M4-S-XXX) instead. MODULYS GP2 (M4-S-XXX) is not affected by the above vulnerabilities.\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eSocomec reports that MODULYS GP (MOD3GP-SY-120K) is an End-of-Life product. Socomec recommends using MODULYS GP2 (M4-S-XXX) instead. MODULYS GP2 (M4-S-XXX) is not affected by the above vulnerabilities.\u003c/span\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"datePublic\": \"2023-09-07T17:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-250-03\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\nA potential attacker with or without (cookie theft) access to the device would be able to include malicious code (XSS) when uploading new device configuration that could affect the intended function of the device.\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA potential attacker with or without (cookie theft) access to the device would be able to include malicious code (XSS) when uploading new device configuration that could affect the intended function of the device.\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Cross-site Scripting\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2023-09-18T20:08:05.295Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-38255\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T17:39:12.120Z\", \"dateReserved\": \"2023-09-06T15:41:16.539Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2023-09-18T20:08:05.295Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…