CVE-2023-32658 (GCVE-0-2023-32658)
Vulnerability from cvelistv5
Published
2023-11-14 19:04
Modified
2024-08-30 17:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- escalation of privilege
- CWE-428 - Unquoted search path
Summary
Unquoted search path in some Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software before version 1.79.1.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software |
Version: before version 1.79.1.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:25:36.327Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software:intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software",
"vendor": "intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software",
"versions": [
{
"lessThan": "1.79.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32658",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-30T16:57:45.630916Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-30T17:03:01.364Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 1.79.1.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unquoted search path in some Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software before version 1.79.1.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
},
{
"cweId": "CWE-428",
"description": "Unquoted search path",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T19:04:45.847Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-32658",
"datePublished": "2023-11-14T19:04:45.847Z",
"dateReserved": "2023-06-02T03:00:03.850Z",
"dateUpdated": "2024-08-30T17:03:01.364Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html\", \"name\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T15:25:36.327Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-32658\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-30T16:57:45.630916Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software:intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software:*:*:*:*:*:*:*:*\"], \"vendor\": \"intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software\", \"product\": \"intel_nuc_kits_nuc7i3dn_nuc7i5dn_nuc7i7dn_hdmi_firmware_update_tool_software\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.79.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-30T17:02:56.267Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.7, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software\", \"versions\": [{\"status\": \"affected\", \"version\": \"before version 1.79.1.1\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html\", \"name\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00908.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Unquoted search path in some Intel(R) NUC Kits NUC7i3DN, NUC7i5DN, NUC7i7DN HDMI firmware update tool software before version 1.79.1.1 may allow an authenticated user to potentially enable escalation of privilege via local access.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"escalation of privilege\"}, {\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-428\", \"description\": \"Unquoted search path\"}]}], \"providerMetadata\": {\"orgId\": \"6dda929c-bb53-4a77-a76d-48e79601a1ce\", \"shortName\": \"intel\", \"dateUpdated\": \"2023-11-14T19:04:45.847Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-32658\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-30T17:03:01.364Z\", \"dateReserved\": \"2023-06-02T03:00:03.850Z\", \"assignerOrgId\": \"6dda929c-bb53-4a77-a76d-48e79601a1ce\", \"datePublished\": \"2023-11-14T19:04:45.847Z\", \"assignerShortName\": \"intel\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…