CVE-2023-31154 (GCVE-0-2023-31154)
Vulnerability from cvelistv5
Published
2023-05-10 19:22
Modified
2025-01-24 19:05
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-3505 Version: R132-V0   < R150-V2
Version: R132-V0   < R149-V4
Version: R132-V0   < R148-V7
Version: R132-V0   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3505-3 Version: R132-V0   < R150-V2
Version: R132-V0   < R149-V4
Version: R132-V0   < R148-V7
Version: R132-V0   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3530 Version: R132-V0   < R150-V2
Version: R132-V0   < R149-V4
Version: R132-V0   < R148-V7
Version: R132-V0   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3530-4 Version: R132-V0   < R150-V2
Version: R132-V0   < R149-V4
Version: R132-V0   < R148-V7
Version: R132-V0   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3532 Version: R132-V0   < R150-V2
Version: R132-V0   < R149-V4
Version: R132-V0   < R148-V7
Version: R132-V0   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3555 Version: R134-V0   < R150-V2
Version: R134-V0   < R149-V4
Version: R134-V0   < R148-V7
Version: R134-V0   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3560S Version: R144-V2   < R150-V2
Version: R144-V2   < R149-V4
Version: R144-V2   < R148-V7
Version: R144-V2   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3560E Version: R144-V2   < R150-V2
Version: R144-V2   < R149-V4
Version: R144-V2   < R148-V7
Version: R144-V2   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-2241 RTAC module Version: R132-V0   < R150-V2
Version: R132-V0   < R149-V4
Version: R132-V0   < R148-V7
Version: R132-V0   < R147-V6
Create a notification for this product.
   Schweitzer Engineering Laboratories SEL-3350 Version: R148-V0   < R150-V2
Version: R148-V0   < R149-V4
Version: R148-V0   < R148-V7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31154",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-24T19:05:17.174236Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-24T19:05:24.335Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web management interface"
          ],
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca, Nozomi Networks"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\n\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:22:18.749Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper Neutralization of Input During Web Page Generation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31154",
    "datePublished": "2023-05-10T19:22:18.749Z",
    "dateReserved": "2023-04-24T23:19:04.958Z",
    "dateUpdated": "2025-01-24T19:05:24.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://selinc.com/support/security-notifications/external-reports/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.nozominetworks.com/blog/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T14:45:25.675Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-31154\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-24T19:05:17.174236Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-24T19:05:13.898Z\"}}], \"cna\": {\"title\": \"Improper Neutralization of Input During Web Page Generation\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Andrea Palanca, Nozomi Networks\"}], \"impacts\": [{\"capecId\": \"CAPEC-242\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-242 Code Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3505\", \"versions\": [{\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3505-3\", \"versions\": [{\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3530\", \"versions\": [{\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3530-4\", \"versions\": [{\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3532\", \"versions\": [{\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3555\", \"versions\": [{\"status\": \"affected\", \"version\": \"R134-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R134-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R134-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R134-V0\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3560S\", \"versions\": [{\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3560E\", \"versions\": [{\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R144-V2\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-2241 RTAC module\", \"versions\": [{\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R132-V0\", \"lessThan\": \"R147-V6\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schweitzer Engineering Laboratories\", \"modules\": [\"Web management interface\"], \"product\": \"SEL-3350\", \"versions\": [{\"status\": \"affected\", \"version\": \"R148-V0\", \"lessThan\": \"R150-V2\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R148-V0\", \"lessThan\": \"R149-V4\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"R148-V0\", \"lessThan\": \"R148-V7\", \"versionType\": \"custom\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-05-10T07:00:00.000Z\", \"references\": [{\"url\": \"https://selinc.com/support/security-notifications/external-reports/\"}, {\"url\": \"https://www.nozominetworks.com/blog/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\\n\\n\\n\\n\\n\\nSee SEL Service Bulletin dated 2022-11-15 for more details.\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cdiv\u003e\u003cdiv\u003eAn Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\u003c/div\u003e\u003c/div\u003e\\n\\n\u003cp\u003eSee SEL Service Bulletin dated 2022-11-15 for more details.\u003cbr\u003e\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"5804bb70-792c-43e0-8596-486cc0efe699\", \"shortName\": \"SEL\", \"dateUpdated\": \"2023-05-10T19:22:18.749Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-31154\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-24T19:05:24.335Z\", \"dateReserved\": \"2023-04-24T23:19:04.958Z\", \"assignerOrgId\": \"5804bb70-792c-43e0-8596-486cc0efe699\", \"datePublished\": \"2023-05-10T19:22:18.749Z\", \"assignerShortName\": \"SEL\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…