CVE-2023-28074 (GCVE-0-2023-28074)
Vulnerability from cvelistv5
Published
2024-07-31 07:56
Modified
2024-08-20 16:31
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
Dell BSAFE Crypto-C Micro Edition, version 4.1.5, and Dell BSAFE Micro Edition Suite, versions 4.0 through 4.6.1 and version 5.0, contains an Out-of-bounds Read vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information exposure.
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dell | Dell BSAFE Micro Edition Suite |
Version: 5.0 |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28074",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T17:45:55.850147Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T17:46:14.672Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell BSAFE Micro Edition Suite",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "5.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell BSAFE Micro Edition Suite",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "4.6.1",
"status": "affected",
"version": "4.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell BSAFE Crypto-C Micro Edition",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "4.1.5",
"status": "affected",
"version": "4.0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-04-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell BSAFE Crypto-C Micro Edition, version 4.1.5, and Dell BSAFE Micro Edition Suite, versions 4.0 through 4.6.1 and version 5.0, contains an Out-of-bounds Read vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"value": "Dell BSAFE Crypto-C Micro Edition, version 4.1.5, and Dell BSAFE Micro Edition Suite, versions 4.0 through 4.6.1 and version 5.0, contains an Out-of-bounds Read vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-20T16:31:10.234Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000212325/dsa-2023-120-dell-bsafe-micro-edition-suite-security-update"
}
],
"source": {
"discovery": "UNKNOWN"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue can be mitigated by a workaround, if customer\u2019s implementations are deemed to be vulnerable. Customers with an active maintenance contract can contact BSAFE Support for details about the workaround.\u003cbr\u003e"
}
],
"value": "This issue can be mitigated by a workaround, if customer\u2019s implementations are deemed to be vulnerable. Customers with an active maintenance contract can contact BSAFE Support for details about the workaround."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-28074",
"datePublished": "2024-07-31T07:56:01.652Z",
"dateReserved": "2023-03-10T05:07:55.140Z",
"dateUpdated": "2024-08-20T16:31:10.234Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…