CVE-2023-24544 (GCVE-0-2023-24544)
Vulnerability from cvelistv5
Published
2023-04-11 00:00
Modified
2025-02-11 16:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Improper access control
Summary
Improper access control vulnerability in Buffalo network devices allows a network-adjacent attacker to obtain specific files of the product. As a result, the product settings may be altered. The affected products and versions are as follows: BS-GSL2024 firmware Ver. 1.10-0.03 and earlier, BS-GSL2016P firmware Ver. 1.10-0.03 and earlier, BS-GSL2016 firmware Ver. 1.10-0.03 and earlier, BS-GS2008 firmware Ver. 1.0.10.01 and earlier, BS-GS2016 firmware Ver. 1.0.10.01 and earlier, BS-GS2024 firmware Ver. 1.0.10.01 and earlier, BS-GS2048 firmware Ver. 1.0.10.01 and earlier, BS-GS2008P firmware Ver. 1.0.10.01 and earlier, BS-GS2016P firmware Ver. 1.0.10.01 and earlier, and BS-GS2024P firmware Ver. 1.0.10.01 and earlier
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| BUFFALO INC. | BS-GSL and BS-GS series |
Version: BS-GSL2024 firmware Ver. 1.10-0.03 and earlier, BS-GSL2016P firmware Ver. 1.10-0.03 and earlier, BS-GSL2016 firmware Ver. 1.10-0.03 and earlier, BS-GS2008 firmware Ver. 1.0.10.01 and earlier, BS-GS2016 firmware Ver. 1.0.10.01 and earlier, BS-GS2024 firmware Ver. 1.0.10.01 and earlier, BS-GS2048 firmware Ver. 1.0.10.01 and earlier, BS-GS2008P firmware Ver. 1.0.10.01 and earlier, BS-GS2016P firmware Ver. 1.0.10.01 and earlier, and BS-GS2024P firmware Ver. 1.0.10.01 and earlier |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:03:17.742Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.buffalo.jp/news/detail/20230310-01.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU96824262/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-24544",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T16:49:44.037429Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T16:50:19.055Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BS-GSL and BS-GS series",
"vendor": "BUFFALO INC.",
"versions": [
{
"status": "affected",
"version": "BS-GSL2024 firmware Ver. 1.10-0.03 and earlier, BS-GSL2016P firmware Ver. 1.10-0.03 and earlier, BS-GSL2016 firmware Ver. 1.10-0.03 and earlier, BS-GS2008 firmware Ver. 1.0.10.01 and earlier, BS-GS2016 firmware Ver. 1.0.10.01 and earlier, BS-GS2024 firmware Ver. 1.0.10.01 and earlier, BS-GS2048 firmware Ver. 1.0.10.01 and earlier, BS-GS2008P firmware Ver. 1.0.10.01 and earlier, BS-GS2016P firmware Ver. 1.0.10.01 and earlier, and BS-GS2024P firmware Ver. 1.0.10.01 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control vulnerability in Buffalo network devices allows a network-adjacent attacker to obtain specific files of the product. As a result, the product settings may be altered. The affected products and versions are as follows: BS-GSL2024 firmware Ver. 1.10-0.03 and earlier, BS-GSL2016P firmware Ver. 1.10-0.03 and earlier, BS-GSL2016 firmware Ver. 1.10-0.03 and earlier, BS-GS2008 firmware Ver. 1.0.10.01 and earlier, BS-GS2016 firmware Ver. 1.0.10.01 and earlier, BS-GS2024 firmware Ver. 1.0.10.01 and earlier, BS-GS2048 firmware Ver. 1.0.10.01 and earlier, BS-GS2008P firmware Ver. 1.0.10.01 and earlier, BS-GS2016P firmware Ver. 1.0.10.01 and earlier, and BS-GS2024P firmware Ver. 1.0.10.01 and earlier"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper access control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T00:00:00.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.buffalo.jp/news/detail/20230310-01.html"
},
{
"url": "https://jvn.jp/en/vu/JVNVU96824262/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-24544",
"datePublished": "2023-04-11T00:00:00.000Z",
"dateReserved": "2023-02-26T00:00:00.000Z",
"dateUpdated": "2025-02-11T16:50:19.055Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.buffalo.jp/news/detail/20230310-01.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://jvn.jp/en/vu/JVNVU96824262/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T11:03:17.742Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.1, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-24544\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-11T16:49:44.037429Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284 Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-11T16:49:33.890Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"BUFFALO INC.\", \"product\": \"BS-GSL and BS-GS series\", \"versions\": [{\"status\": \"affected\", \"version\": \"BS-GSL2024 firmware Ver. 1.10-0.03 and earlier, BS-GSL2016P firmware Ver. 1.10-0.03 and earlier, BS-GSL2016 firmware Ver. 1.10-0.03 and earlier, BS-GS2008 firmware Ver. 1.0.10.01 and earlier, BS-GS2016 firmware Ver. 1.0.10.01 and earlier, BS-GS2024 firmware Ver. 1.0.10.01 and earlier, BS-GS2048 firmware Ver. 1.0.10.01 and earlier, BS-GS2008P firmware Ver. 1.0.10.01 and earlier, BS-GS2016P firmware Ver. 1.0.10.01 and earlier, and BS-GS2024P firmware Ver. 1.0.10.01 and earlier\"}]}], \"references\": [{\"url\": \"https://www.buffalo.jp/news/detail/20230310-01.html\"}, {\"url\": \"https://jvn.jp/en/vu/JVNVU96824262/\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper access control vulnerability in Buffalo network devices allows a network-adjacent attacker to obtain specific files of the product. As a result, the product settings may be altered. The affected products and versions are as follows: BS-GSL2024 firmware Ver. 1.10-0.03 and earlier, BS-GSL2016P firmware Ver. 1.10-0.03 and earlier, BS-GSL2016 firmware Ver. 1.10-0.03 and earlier, BS-GS2008 firmware Ver. 1.0.10.01 and earlier, BS-GS2016 firmware Ver. 1.0.10.01 and earlier, BS-GS2024 firmware Ver. 1.0.10.01 and earlier, BS-GS2048 firmware Ver. 1.0.10.01 and earlier, BS-GS2008P firmware Ver. 1.0.10.01 and earlier, BS-GS2016P firmware Ver. 1.0.10.01 and earlier, and BS-GS2024P firmware Ver. 1.0.10.01 and earlier\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Improper access control\"}]}], \"providerMetadata\": {\"orgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"shortName\": \"jpcert\", \"dateUpdated\": \"2023-04-11T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-24544\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-11T16:50:19.055Z\", \"dateReserved\": \"2023-02-26T00:00:00.000Z\", \"assignerOrgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"datePublished\": \"2023-04-11T00:00:00.000Z\", \"assignerShortName\": \"jpcert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.