CVE-2023-2374 (GCVE-0-2023-2374)
Vulnerability from cvelistv5
Published
2023-04-28 14:31
Modified
2024-08-02 06:19
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VLAI Severity ?
EPSS score ?
CWE
- CWE-77 - Command Injection
Summary
A vulnerability has been found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6 and classified as critical. This vulnerability affects unknown code of the component Web Management Interface. The manipulation of the argument ecn-down leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-227650 is the identifier assigned to this vulnerability.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti | EdgeRouter X |
Version: 2.0.9-hotfix.0 Version: 2.0.9-hotfix.1 Version: 2.0.9-hotfix.2 Version: 2.0.9-hotfix.3 Version: 2.0.9-hotfix.4 Version: 2.0.9-hotfix.5 Version: 2.0.9-hotfix.6 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:19:14.979Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.227650"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.227650"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/leetsun/IoT/tree/main/EdgeRouterX/CI/6"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Management Interface"
],
"product": "EdgeRouter X",
"vendor": "Ubiquiti",
"versions": [
{
"status": "affected",
"version": "2.0.9-hotfix.0"
},
{
"status": "affected",
"version": "2.0.9-hotfix.1"
},
{
"status": "affected",
"version": "2.0.9-hotfix.2"
},
{
"status": "affected",
"version": "2.0.9-hotfix.3"
},
{
"status": "affected",
"version": "2.0.9-hotfix.4"
},
{
"status": "affected",
"version": "2.0.9-hotfix.5"
},
{
"status": "affected",
"version": "2.0.9-hotfix.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "leetmoon (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6 and classified as critical. This vulnerability affects unknown code of the component Web Management Interface. The manipulation of the argument ecn-down leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-227650 is the identifier assigned to this vulnerability."
},
{
"lang": "de",
"value": "In Ubiquiti EdgeRouter X bis 2.0.9-hotfix.6 wurde eine kritische Schwachstelle gefunden. Es geht um eine nicht n\u00e4her bekannte Funktion der Komponente Web Management Interface. Mittels dem Manipulieren des Arguments ecn-down mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-22T18:31:51.401Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.227650"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.227650"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/leetsun/IoT/tree/main/EdgeRouterX/CI/6"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-04-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-04-28T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-04-28T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-05-21T15:13:09.000Z",
"value": "VulDB entry last update"
}
],
"title": "Ubiquiti EdgeRouter X Web Management Interface command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-2374",
"datePublished": "2023-04-28T14:31:04.038Z",
"dateReserved": "2023-04-28T11:29:52.832Z",
"dateUpdated": "2024-08-02T06:19:14.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…