CVE-2023-1492 (GCVE-0-2023-1492)
Vulnerability from cvelistv5
Published
2023-03-18 22:31
Modified
2024-08-02 05:49
CWE
Summary
A vulnerability was found in Max Secure Anti Virus Plus 19.0.2.1. It has been declared as problematic. This vulnerability affects the function 0x220019 in the library MaxProc64.sys of the component IoControlCode Handler. The manipulation of the argument SystemBuffer leads to denial of service. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. VDB-223378 is the identifier assigned to this vulnerability.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:49:11.670Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.223378"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.223378"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1492"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1G_Szy4kCrZU-whGbVcxpdE1yKf5Vxqq3/view"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "IoControlCode Handler"
          ],
          "product": "Anti Virus Plus",
          "vendor": "Max Secure",
          "versions": [
            {
              "status": "affected",
              "version": "19.0.2.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "Zeze7w (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Max Secure Anti Virus Plus 19.0.2.1. It has been declared as problematic. This vulnerability affects the function 0x220019 in the library MaxProc64.sys of the component IoControlCode Handler. The manipulation of the argument SystemBuffer leads to denial of service. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. VDB-223378 is the identifier assigned to this vulnerability."
        },
        {
          "lang": "de",
          "value": "In Max Secure Anti Virus Plus 19.0.2.1 wurde eine Schwachstelle ausgemacht. Sie wurde als problematisch eingestuft. Dabei geht es um die Funktion 0x220019 in der Bibliothek MaxProc64.sys der Komponente IoControlCode Handler. Dank Manipulation des Arguments SystemBuffer mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs hat dabei lokal zu erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4.6,
            "vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "CWE-404 Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-21T09:34:02.324Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.223378"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.223378"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1492"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://drive.google.com/file/d/1G_Szy4kCrZU-whGbVcxpdE1yKf5Vxqq3/view"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-03-18T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-03-18T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-03-18T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-04-11T20:03:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Max Secure Anti Virus Plus IoControlCode MaxProc64.sys 0x220019 denial of service"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-1492",
    "datePublished": "2023-03-18T22:31:03.586Z",
    "dateReserved": "2023-03-18T20:20:37.430Z",
    "dateUpdated": "2024-08-02T05:49:11.670Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…