CVE-2022-39147 (GCVE-0-2022-39147)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-824 - Access of Uninitialized Pointer
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)
References
| ► | URL | Tags | |||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ► | Siemens | Parasolid V33.1 |
Version: All versions < V33.1.262 |
||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.568Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824: Access of Uninitialized Pointer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:03",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39147",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-824: Access of Uninitialized Pointer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39147",
"datePublished": "2022-09-13T09:41:03",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.568Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…