CVE-2022-33871 (GCVE-0-2022-33871)
Vulnerability from cvelistv5
Published
2023-02-16 18:06
Modified
2024-10-23 14:47
CWE
Summary
A stack-based buffer overflow vulnerability [CWE-121] in FortiWeb version 7.0.1 and earlier, 6.4 all versions, version 6.3.19 and earlier may allow a privileged attacker to execute arbitrary code or commands via specifically crafted CLI `execute backup-local rename` and `execute backup-local show` operations.
Impacted products
Vendor Product Version
Fortinet FortiWeb Version: 7.0.0    7.0.1
Version: 6.4.0    6.4.2
Version: 6.3.6    6.3.19
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:09:22.682Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-22-164",
            "tags": [
              "x_transferred"
            ],
            "url": "https://fortiguard.com/psirt/FG-IR-22-164"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-33871",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T14:11:48.320208Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T14:47:25.480Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FortiWeb",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.0.1",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.4.2",
              "status": "affected",
              "version": "6.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.3.19",
              "status": "affected",
              "version": "6.3.6",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack-based buffer overflow vulnerability [CWE-121] in FortiWeb version 7.0.1 and earlier, 6.4 all versions, version 6.3.19 and earlier may allow a privileged attacker to execute arbitrary code or commands via specifically crafted CLI `execute backup-local rename` and `execute backup-local show` operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Denial of service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-16T18:06:11.661Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.com/psirt/FG-IR-22-164",
          "url": "https://fortiguard.com/psirt/FG-IR-22-164"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiWeb version 7.0.2 or above\r\nPlease upgrade to FortiWeb version 6.3.20 or above"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2022-33871",
    "datePublished": "2023-02-16T18:06:11.661Z",
    "dateReserved": "2022-06-16T11:14:43.763Z",
    "dateUpdated": "2024-10-23T14:47:25.480Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…