CVE-2022-3192 (GCVE-0-2022-3192)
Vulnerability from cvelistv5
Published
2023-03-31 16:13
Modified
2025-02-11 18:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Summary
Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:00:10.643Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3192",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T18:39:53.320995Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T18:40:07.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://abb.com/plc",
"defaultStatus": "unknown",
"packageName": "PM5xx",
"product": "AC500 V2",
"vendor": "ABB",
"versions": [
{
"lessThan": "2.8.6",
"status": "affected",
"version": "2.0.0",
"versionType": "release"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB thanks the following for working with us to help protect customers: CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.\u003cp\u003eThis issue affects AC500 V2: from 2.0.0 before 2.8.6.\u003c/p\u003e"
}
],
"value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-220",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-220 Client-Server Protocol Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-13T03:57:46.530Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": " Improper Check for Unusual or Exceptional Conditions",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eUse the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis protocol/port is not affected by the DoS impact of the vulnerability.\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \n\n\nThis protocol/port is not affected by the DoS impact of the vulnerability.\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-3192",
"datePublished": "2023-03-31T16:13:13.149Z",
"dateReserved": "2022-09-13T05:57:45.421Z",
"dateUpdated": "2025-02-11T18:40:07.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T01:00:10.643Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-3192\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-11T18:39:53.320995Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-11T18:39:29.971Z\"}}], \"cna\": {\"title\": \" Improper Check for Unusual or Exceptional Conditions\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"ABB thanks the following for working with us to help protect customers: CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure.\"}], \"impacts\": [{\"capecId\": \"CAPEC-220\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-220 Client-Server Protocol Manipulation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"ABB\", \"product\": \"AC500 V2\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.0.0\", \"lessThan\": \"2.8.6\", \"versionType\": \"release\"}], \"packageName\": \"PM5xx\", \"collectionURL\": \"https://abb.com/plc\", \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Use the communication protocol \\\"Tcp/Ip\\\" instead of \\\"ABB Tcp/Ip Level 2\\\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \\n\\n\\nThis protocol/port is not affected by the DoS impact of the vulnerability.\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003eUse the communication protocol \\\"Tcp/Ip\\\" instead of \\\"ABB Tcp/Ip Level 2\\\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis protocol/port is not affected by the DoS impact of the vulnerability.\u003cbr\u003e\u003c/div\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.\u003cp\u003eThis issue affects AC500 V2: from 2.0.0 before 2.8.6.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-754\", \"description\": \"CWE-754 Improper Check for Unusual or Exceptional Conditions\"}]}], \"providerMetadata\": {\"orgId\": \"2b718523-d88f-4f37-9bbd-300c20644bf9\", \"shortName\": \"ABB\", \"dateUpdated\": \"2023-09-13T03:57:46.530Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-3192\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-11T18:40:07.850Z\", \"dateReserved\": \"2022-09-13T05:57:45.421Z\", \"assignerOrgId\": \"2b718523-d88f-4f37-9bbd-300c20644bf9\", \"datePublished\": \"2023-03-31T16:13:13.149Z\", \"assignerShortName\": \"ABB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…