CVE-2022-27806 (GCVE-0-2022-27806)
Vulnerability from cvelistv5
Published
2022-05-05 16:29
Modified
2024-09-17 01:36
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Summary
On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
References
Impacted products
Vendor Product Version
F5 BIG-IP (Advanced WAF, APM, ASM) Version: 16.1.x
Version: 15.1.x
Version: 14.1.x
Version: 13.1.x
Version: 12.1.x
Version: 11.6.x
Patch: 17.0.0   < 17.0.x*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:32:59.981Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K68647001"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIG-IP (Advanced WAF, APM, ASM)",
          "vendor": "F5",
          "versions": [
            {
              "status": "affected",
              "version": "16.1.x"
            },
            {
              "status": "affected",
              "version": "15.1.x"
            },
            {
              "status": "affected",
              "version": "14.1.x"
            },
            {
              "status": "affected",
              "version": "13.1.x"
            },
            {
              "status": "affected",
              "version": "12.1.x"
            },
            {
              "status": "affected",
              "version": "11.6.x"
            },
            {
              "lessThan": "17.0.x*",
              "status": "unaffected",
              "version": "17.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "BIG-IP Guided Configuration (GC)",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "9.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-05T16:29:58",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K68647001"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
          "ID": "CVE-2022-27806",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIG-IP (Advanced WAF, APM, ASM)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "!\u003e=",
                            "version_name": "17.0.x",
                            "version_value": "17.0.0"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "16.1.x",
                            "version_value": "16.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "15.1.x",
                            "version_value": "15.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "14.1.x",
                            "version_value": "14.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "13.1.x",
                            "version_value": "13.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "12.1.x",
                            "version_value": "12.1.x"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "11.6.x",
                            "version_value": "11.6.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "BIG-IP Guided Configuration (GC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "F5"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On all versions of 16.1.x, 15.1.x, 14.1.x, 13.1.x, 12.1.x, and 11.6.x of F5 BIG-IP Advanced WAF, ASM, and ASM, and F5 BIG-IP Guided Configuration (GC) all versions prior to 9.0, when running in Appliance mode, an authenticated attacker assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing command injection vulnerabilities in undisclosed URIs in F5 BIG-IP Guided Configuration. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K68647001",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K68647001"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2022-27806",
    "datePublished": "2022-05-05T16:29:58.078244Z",
    "dateReserved": "2022-04-19T00:00:00",
    "dateUpdated": "2024-09-17T01:36:21.373Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…