CVE-2022-2758 (GCVE-0-2022-2758)

Vulnerability from cvelistv5 – Published: 2022-08-31 15:33 – Updated: 2025-04-16 16:11
VLAI
Title
Update
Summary
Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:50 UTC
CWE
  • CWE-326 - Inadequate Encryption Strength
Assigner
icscert CNA
Date Public
2022-08-16 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:46:04.435Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2758",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:50:15.763986Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:11:29.230Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "XG5000",
          "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
          "versions": [
            {
              "lessThan": "V4.0",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PLC: XGB-XECH",
          "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
          "versions": [
            {
              "lessThan": "V1.30",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PLC: XGB-XBCH",
          "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
          "versions": [
            {
              "lessThan": "V1.90",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PLC: XGB-XBMS",
          "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
          "versions": [
            {
              "lessThan": "V3.00",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PLC: XGR-CPUH",
          "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
          "versions": [
            {
              "lessThan": "V1.80",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PLC: XGI-CPUU/UD/H/S/E",
          "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
          "versions": [
            {
              "lessThan": "V3.20",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PLC: XGK-CPUU/H/A/S/E",
          "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
          "versions": [
            {
              "lessThan": "V3.50",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Hong-Gi Kin of the Korea Internet \u0026 Security Agency (KISA) reported this vulnerability."
        }
      ],
      "datePublic": "2022-08-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC\u2019s communication traffic."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T00:00:00.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Update",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2758",
    "datePublished": "2022-08-31T15:33:03.944Z",
    "dateReserved": "2022-08-10T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:11:29.230Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:46:04.435Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-02"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2758",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:50:15.763986Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T15:50:17.259Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "XG5000",
              "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
              "versions": [
                {
                  "lessThan": "V4.0",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "PLC: XGB-XECH",
              "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
              "versions": [
                {
                  "lessThan": "V1.30",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "PLC: XGB-XBCH",
              "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
              "versions": [
                {
                  "lessThan": "V1.90",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "PLC: XGB-XBMS",
              "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
              "versions": [
                {
                  "lessThan": "V3.00",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "PLC: XGR-CPUH",
              "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
              "versions": [
                {
                  "lessThan": "V1.80",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "PLC: XGI-CPUU/UD/H/S/E",
              "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
              "versions": [
                {
                  "lessThan": "V3.20",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "PLC: XGK-CPUU/H/A/S/E",
              "vendor": "LS Industrial Systems (LSIS) Co. Ltd LS Electric",
              "versions": [
                {
                  "lessThan": "V3.50",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Hong-Gi Kin of the Korea Internet \u0026 Security Agency (KISA) reported this vulnerability."
            }
          ],
          "datePublic": "2022-08-16T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC\u2019s communication traffic."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-326",
                  "description": "CWE-326 Inadequate Encryption Strength",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T00:00:00.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-02"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Update",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2758",
        "datePublished": "2022-08-31T15:33:03.944Z",
        "dateReserved": "2022-08-10T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:11:29.230Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.