CVE-2022-26649 (GCVE-0-2022-26649)
Vulnerability from cvelistv5
Published
2022-07-12 10:06
Modified
2025-04-21 13:51
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.
Impacted products
Vendor Product Version
Siemens SCALANCE X200-4P IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X201-3P IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X201-3P IRT PRO Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X202-2IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X202-2IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X202-2P IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X202-2P IRT PRO Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X204-2 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X204-2FM Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X204-2LD Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X204-2LD TS Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X204-2TS Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X204IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X204IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X204IRT PRO Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE X206-1 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X206-1LD Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X208 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X208PRO Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X212-2 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X212-2LD Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X216 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE X224 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE XF201-3P IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE XF202-2P IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE XF204 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE XF204-2 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE XF204-2BA IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE XF204IRT Version: All versions < V5.5.2
Create a notification for this product.
   Siemens SCALANCE XF206-1 Version: All versions < V5.2.6
Create a notification for this product.
   Siemens SCALANCE XF208 Version: All versions < V5.2.6
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:11:43.372Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26649",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:23:07.279089Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:51:58.286Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:02:21.918Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26649",
    "datePublished": "2022-07-12T10:06:35.000Z",
    "dateReserved": "2022-03-07T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:51:58.286Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T05:11:43.372Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-26649\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-18T15:23:07.279089Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-18T15:23:09.174Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 9.6, \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SCALANCE X200-4P IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X201-3P IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X201-3P IRT PRO\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X202-2IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X202-2IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X202-2P IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X202-2P IRT PRO\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204-2\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204-2FM\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204-2LD\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204-2LD TS\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204-2TS\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X204IRT PRO\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X206-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X206-1LD\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X208\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X208PRO\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X212-2\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X212-2LD\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X216\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE X224\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF201-3P IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF202-2P IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204-2\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204-2BA IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204IRT\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.5.2\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF206-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF208\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V5.2.6\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-04-11T09:02:21.918Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-26649\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-21T13:51:58.286Z\", \"dateReserved\": \"2022-03-07T00:00:00.000Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2022-07-12T10:06:35.000Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…