CVE-2022-2662 (GCVE-0-2022-2662)

Vulnerability from cvelistv5 – Published: 2022-08-16 19:52 – Updated: 2025-04-16 17:50
VLAI
Title
Sequi PortBloque S Improper Authentication
Summary
Sequi PortBloque S has a improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 17:28 UTC
CWE
  • CWE-287 - Improper Authentication
Assigner
icscert CNA
References
Impacted products
Vendor Product Version
Sequi PortBloque S Affected: All
Create a notification for this product.
Date Public
2022-08-16 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:46:03.638Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2662",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:28:07.011925Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:50:46.946Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PortBloque S",
          "vendor": "Sequi",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Byron Chaney of Accenture Security reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2022-08-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Sequi PortBloque S has a improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-16T19:52:40.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Sequi PortBloque S Improper Authentication",
      "workarounds": [
        {
          "lang": "en",
          "value": "Users should take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from business networks.\nWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-16T17:26:00.000Z",
          "ID": "CVE-2022-2662",
          "STATE": "PUBLIC",
          "TITLE": "Sequi PortBloque S Improper Authentication"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PortBloque S",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Sequi"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Byron Chaney of Accenture Security reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Sequi PortBloque S has a improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287 Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Users should take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from business networks.\nWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2662",
    "datePublished": "2022-08-16T19:52:40.809Z",
    "dateReserved": "2022-08-04T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:50:46.946Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:46:03.638Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2662",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:28:07.011925Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:28:08.299Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "PortBloque S",
              "vendor": "Sequi",
              "versions": [
                {
                  "status": "affected",
                  "version": "All"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Byron Chaney of Accenture Security reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-08-16T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Sequi PortBloque S has a improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-16T19:52:40.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Sequi PortBloque S Improper Authentication",
          "workarounds": [
            {
              "lang": "en",
              "value": "Users should take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from business networks.\nWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-08-16T17:26:00.000Z",
              "ID": "CVE-2022-2662",
              "STATE": "PUBLIC",
              "TITLE": "Sequi PortBloque S Improper Authentication"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "PortBloque S",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "All"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Sequi"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Byron Chaney of Accenture Security reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Sequi PortBloque S has a improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-07"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Users should take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from business networks.\nWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2662",
        "datePublished": "2022-08-16T19:52:40.809Z",
        "dateReserved": "2022-08-04T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:50:46.946Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.