CVE-2022-24286 (GCVE-0-2022-24286)
Vulnerability from cvelistv5
Published
2022-03-08 22:32
Modified
2024-08-03 04:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Acer QuickAccess 2.01.300x before 2.01.3030 and 3.00.30xx before 3.00.3038 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.361Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.acer.com/en/kb/articles/14762"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Acer QuickAccess 2.01.300x before 2.01.3030 and 3.00.30xx before 3.00.3038 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-08T22:32:50.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.acer.com/en/kb/articles/14762"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-24286",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Acer QuickAccess 2.01.300x before 2.01.3030 and 3.00.30xx before 3.00.3038 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.acer.com/en/kb/articles/14762",
"refsource": "MISC",
"url": "https://community.acer.com/en/kb/articles/14762"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-24286",
"datePublished": "2022-03-08T22:32:50.000Z",
"dateReserved": "2022-01-31T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:07:02.361Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…