CVE-2022-22511 (GCVE-0-2022-22511)

Vulnerability from cvelistv5 – Published: 2022-03-09 19:38 – Updated: 2024-09-17 00:16
VLAI
Title
WAGO PLCs WBM vulnerable to reflected XSS
Summary
Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
CERTVDE CNA
References
Date Public
2022-03-09 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.300Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Compact Controller CC100 (751-9301)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Edge Controller (752-8303/8000-002)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Series PFC100 (750-81xx/xxx-xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Series PFC200 (750-82xx/xxx-xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "status": "affected",
              "version": "FW16 FW22"
            }
          ]
        },
        {
          "product": "Series Touch Panel 600 Marine Line (762-6xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "status": "affected",
              "version": "FW16 FW22"
            }
          ]
        },
        {
          "product": "Series Touch Panel 600 Standard Line (762-4xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "status": "affected",
              "version": "FW16 FW22"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
        }
      ],
      "datePublic": "2022-03-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-09T19:38:43.000Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
        }
      ],
      "source": {
        "advisory": "VDE-2022-004",
        "defect": [
          "CERT@VDE#64068"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "WAGO PLCs WBM vulnerable to reflected XSS",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
          "ID": "CVE-2022-22511",
          "STATE": "PUBLIC",
          "TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Compact Controller CC100 (751-9301)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Edge Controller (752-8303/8000-002)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series PFC100 (750-81xx/xxx-xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series PFC200 (750-82xx/xxx-xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WAGO"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
          }
        ],
        "source": {
          "advisory": "VDE-2022-004",
          "defect": [
            "CERT@VDE#64068"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22511",
    "datePublished": "2022-03-09T19:38:43.516Z",
    "dateReserved": "2022-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:16:00.059Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.