CVE-2022-1704 (GCVE-0-2022-1704)
Vulnerability from cvelistv5
Published
2022-08-05 15:25
Modified
2025-04-16 16:13
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
Summary
Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup.
References
| ► | URL | Tags | |||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Version: 8.1 < Version: All < 7.9.21 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:10:03.916Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1704",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:50:51.760136Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:13:45.512Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"lessThanOrEqual": "8.1.7",
"status": "affected",
"version": "8.1",
"versionType": "custom"
},
{
"lessThan": "7.9.21",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Keval Shah reported this vulnerability to CISA"
}
],
"datePublic": "2022-07-26T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-05T15:25:19.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
}
],
"source": {
"advisory": "ICSA-22-207-01",
"discovery": "EXTERNAL"
},
"title": "Inductive Automation Ignition",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-07-26T17:00:00.000Z",
"ID": "CVE-2022-1704",
"STATE": "PUBLIC",
"TITLE": "Inductive Automation Ignition"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "8.1",
"version_value": "8.1.7"
},
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "7.9.21"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Keval Shah reported this vulnerability to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
}
],
"source": {
"advisory": "ICSA-22-207-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1704",
"datePublished": "2022-08-05T15:25:19.220Z",
"dateReserved": "2022-05-12T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:13:45.512Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T00:10:03.916Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-1704\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T15:50:51.760136Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T15:50:53.429Z\"}}], \"cna\": {\"title\": \"Inductive Automation Ignition\", \"source\": {\"advisory\": \"ICSA-22-207-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"Keval Shah reported this vulnerability to CISA\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 7.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Inductive Automation\", \"product\": \"Ignition\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"8.1.7\"}, {\"status\": \"affected\", \"version\": \"All\", \"lessThan\": \"7.9.21\", \"versionType\": \"custom\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Inductive Automation recommends users upgrade the Ignition software to the latest version:\\n\\nInductive Automation Ignition: Version 8.1.9 or later\\nInductive Automation Ignition: Version 7.9.21 or later\"}], \"datePublic\": \"2022-07-26T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01\", \"tags\": [\"x_refsource_MISC\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-611\", \"description\": \"CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-08-05T15:25:19.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"Keval Shah reported this vulnerability to CISA\"}], \"impact\": {\"cvss\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 7.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}, \"source\": {\"advisory\": \"ICSA-22-207-01\", \"discovery\": \"EXTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_name\": \"8.1\", \"version_value\": \"8.1.7\", \"version_affected\": \"\u003c=\"}, {\"version_name\": \"All\", \"version_value\": \"7.9.21\", \"version_affected\": \"\u003c\"}]}, \"product_name\": \"Ignition\"}]}, \"vendor_name\": \"Inductive Automation\"}]}}, \"solution\": [{\"lang\": \"en\", \"value\": \"Inductive Automation recommends users upgrade the Ignition software to the latest version:\\n\\nInductive Automation Ignition: Version 8.1.9 or later\\nInductive Automation Ignition: Version 7.9.21 or later\"}], \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-1704\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Inductive Automation Ignition\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\", \"DATE_PUBLIC\": \"2022-07-26T17:00:00.000Z\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-1704\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T16:13:45.512Z\", \"dateReserved\": \"2022-05-12T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-08-05T15:25:19.220Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…