CVE-2021-41841 (GCVE-0-2021-41841)
Vulnerability from cvelistv5
Published
2022-02-03 01:04
Modified
2026-08-11 12:22
Severity ?
CWE
  • n/a
Summary
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T19:12:38.619Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge/SA-2022019"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          },
          {
            "url": "https://www.kb.cert.org/vuls/id/796611"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "RUGGEDCOM APE1808 - BIOS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V1.0.202N",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC Field PG M5",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V22.01.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC Field PG M6",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V26.01.13",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC127E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V27.01.09",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC227G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC277G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC\u00a0IPC277G PRO",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC327G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC377G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC427E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC477E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC477E PRO",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC627E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC647E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC677E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC847E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC ITP1000",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V23.01.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIPLUS IPC427E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-11T12:22:13.467Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T19:06:23.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2022019"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-41841",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.insyde.com/security-pledge",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "name": "https://www.insyde.com/security-pledge/SA-2022019",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge/SA-2022019"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220217-0012/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-41841",
    "datePublished": "2022-02-03T01:04:57.000Z",
    "dateReserved": "2021-10-01T00:00:00.000Z",
    "dateUpdated": "2026-08-11T12:22:13.467Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…