CVE-2021-33626 (GCVE-0-2021-33626)
Vulnerability from cvelistv5
Published
2021-10-01 02:21
Modified
2026-08-11 12:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:30.965Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:05.856Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:07:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-33626",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2021001",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0006/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
},
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33626",
"datePublished": "2021-10-01T02:21:29.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:05.856Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…