CVE-2021-31893 (GCVE-0-2021-31893)
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-08-03 23:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.
References
| ► | URL | Tags | |||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ► | Siemens | SIMATIC PCS 7 V8.2 and earlier |
Version: All versions |
|||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:10:30.646Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3"
}
]
},
{
"product": "SIMATIC PDM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.2"
}
]
},
{
"product": "SIMATIC STEP 7 V5.X",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SINAMICS STARTER (containing STEP 7 OEM version)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4 HF2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-13T11:02:56",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-31893",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP3"
}
]
}
},
{
"product_name": "SIMATIC PDM",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.2"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 V5.X",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.6 SP2 HF3"
}
]
}
},
{
"product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.4 HF2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-31893",
"datePublished": "2021-07-13T11:02:56",
"dateReserved": "2021-04-29T00:00:00",
"dateUpdated": "2024-08-03T23:10:30.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…