CVE-2021-23276 (GCVE-0-2021-23276)
Vulnerability from cvelistv5
Published
2021-04-13 18:03
Modified
2024-09-17 02:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - SQL Injection
Summary
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Eaton | Intelligent Power manager (IPM) |
Version: unspecified < 1.69 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:05:54.415Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intelligent Power manager (IPM)",
"vendor": "Eaton",
"versions": [
{
"lessThan": "1.69",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Amir Preminger from Claroty research"
}
],
"datePublic": "2021-04-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 SQL Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-13T18:03:08.000Z",
"orgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759",
"shortName": "Eaton"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "upgrade the software to latest version 1.69"
}
],
"source": {
"advisory": "ETN-VA-2021-1000",
"defect": [
"ETN-VA-2021-1000"
],
"discovery": "EXTERNAL"
},
"title": "Improper Neutralization of Special Elements used in an SQL Command",
"workarounds": [
{
"lang": "en",
"value": "To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 \u0026 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "SQL Injection",
"ASSIGNER": "CybersecurityCOE@eaton.com",
"DATE_PUBLIC": "2021-04-01T07:00:00.000Z",
"ID": "CVE-2021-23276",
"STATE": "PUBLIC",
"TITLE": "Improper Neutralization of Special Elements used in an SQL Command"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intelligent Power manager (IPM)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.69"
}
]
}
}
]
},
"vendor_name": "Eaton"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Amir Preminger from Claroty research"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-89 SQL Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf",
"refsource": "MISC",
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "upgrade the software to latest version 1.69"
}
],
"source": {
"advisory": "ETN-VA-2021-1000",
"defect": [
"ETN-VA-2021-1000"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 \u0026 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759",
"assignerShortName": "Eaton",
"cveId": "CVE-2021-23276",
"datePublished": "2021-04-13T18:03:08.524Z",
"dateReserved": "2021-01-08T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:22:03.243Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.