CVE-2021-21881 (GCVE-0-2021-21881)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
An OS command injection vulnerability exists in the Web Manager Wireless Network Scanner functionality of Lantronix PremierWave 2050 8.9.0.0R4. A specially-crafted HTTP request can lead to command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:23:29.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1325"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Lantronix",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Lantronix PremierWave 2050 8.9.0.0R4 (in QEMU)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An OS command injection vulnerability exists in the Web Manager Wireless Network Scanner functionality of Lantronix PremierWave 2050 8.9.0.0R4. A specially-crafted HTTP request can lead to command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-22T18:06:32.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1325"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21881",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Lantronix",
"version": {
"version_data": [
{
"version_value": "Lantronix PremierWave 2050 8.9.0.0R4 (in QEMU)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An OS command injection vulnerability exists in the Web Manager Wireless Network Scanner functionality of Lantronix PremierWave 2050 8.9.0.0R4. A specially-crafted HTTP request can lead to command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 9.9,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1325",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1325"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2021-21881",
"datePublished": "2021-12-22T18:06:32.000Z",
"dateReserved": "2021-01-04T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:23:29.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…