CVE-2021-0106 (GCVE-0-2021-0106)
Vulnerability from cvelistv5
Published
2021-06-09 19:13
Modified
2024-08-03 15:32
Severity ?
CWE
  • escalation of privilege
Summary
Incorrect default permissions in the Intel(R) Optane(TM) DC Persistent Memory for Windows software versions before 2.00.00.3842 or 1.00.00.3515 may allow an authenticated user to potentially enable escalation of privilege via local access.
Impacted products
Vendor Product Version
n/a Intel(R) Optane(TM) DC Persistent Memory for Windows software versions Version: versions before 2.00.00.3842 or 1.00.00.3515
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:32:09.127Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00541.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel(R) Optane(TM) DC Persistent Memory for Windows software versions",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "versions before 2.00.00.3842 or 1.00.00.3515"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Incorrect default permissions in the Intel(R) Optane(TM) DC Persistent Memory for Windows software versions before 2.00.00.3842 or 1.00.00.3515 may allow an authenticated user to potentially enable escalation of privilege via local access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T19:13:01.000Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00541.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "ID": "CVE-2021-0106",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel(R) Optane(TM) DC Persistent Memory for Windows software versions",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions before 2.00.00.3842 or 1.00.00.3515"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Incorrect default permissions in the Intel(R) Optane(TM) DC Persistent Memory for Windows software versions before 2.00.00.3842 or 1.00.00.3515 may allow an authenticated user to potentially enable escalation of privilege via local access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "escalation of privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00541.html",
              "refsource": "MISC",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00541.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2021-0106",
    "datePublished": "2021-06-09T19:13:01.000Z",
    "dateReserved": "2020-10-22T00:00:00.000Z",
    "dateUpdated": "2024-08-03T15:32:09.127Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…